GROUNDING
Before connecting this device to the power line, the protective earth terminal screws of this device
must be connected to the protective earth in the building installation.
LASER
This equipment is a Class 1 Laser Product in accordance with IEC60825 - 1: 1993 + A1:1997 +
A2:2001 Standard.
FUSES
Make sure that only fuses with the required rated current and of the specified type are used for
replacement. The use of repaired fuses and the short-circuiting of fuse holders must be avoided.
Whenever it is likely that the protection offered by fuses has been impaired, the instrument must be
made inoperative and be secured against any unintended operation.
LINE VOLTAGE
Before connecting this instrument to the power line, make sure the voltage of the power source
matches the requirements of the instrument. Refer to the Specifications for information about the
correct power rating for the device.
48V DC-powered platforms have an input tolerance of 36-72V DC.
SPECIFICATION CHANGES
Specifications are subject to change without notice.
Note:
This equipment has been tested and found to comply with the limits for a Class A digital
device pursuant to Part 15B of the FCC Rules and EN55022 Class A, EN 55024; EN 61000-3-2; EN
61000-3-3; IEC 61000 4-2 to 4-6, IEC 61000 4-8 and IEC 61000-4-11For CE MARK Compliance.
These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user is required to correct
the interference at his own expense.
SPECIAL NOTICE FOR NORTH AMERICAN USERS
For North American power connection, select a power supply cord that is UL Listed and CSA Certified
3 - conductor, [18 AWG], terminated in a molded on plug cap rated 125 V, [10 A], with a minimum
length of 1.5m [six feet] but no longer than 4.5m...For European connection, select a power supply
cord that is internationally harmonized and marked “<HAR>”, 3 - conductor, 0,75 mm2 minimum
mm2 wire, rated 300 V, with a PVC insulated jacket. The cord must have a molded on plug cap rated
250 V, 3 A.
RESTRICT AREA ACCESS
The DC powered equipment should only be installed in a Restricted Access Area.
INSTALLATION CODES
This device must be installed according to country national electrical codes. For North America,
equipment must be installed in accordance with the US National Electrical Code, Articles 110 - 16,
110 -17, and 110 -18 and the Canadian Electrical Code, Section 12.
INTERCONNECTION OF UNITS
Cables for connecting to the unit RS232 and Ethernet Interfaces must be UL certified type DP-1 or
DP-2. (Note- when residing in non LPS circuit)
OVERCURRENT PROTECTION
A readily accessible listed branch-circuit over current protective device rated 15 A must be
incorporated in the building wiring for each power input.