18
pallet scales (load placed on EUR-pallet loaded using pallet truck); middle
block of pallet placed on the scale must remain unsupported:
ramp scales (trucks used in meat plants); it is necessary to select platform
matching the span of truck casters, this is to make sure that in the case
of trucks of weight close to the maximum capacity, the load is transferred
onto the platform close to load-carrying sections (profiles):
10.3. Zeroing
To zero mass indication press
key. Zero indication and the following
pictograms are displayed:
and
.
Zeroing operation means determining new zero point, recognized by
the weighing device as precise zero. The instrument can be zeroed only when
the indication is stable.
Indication can be zeroed only within ±2% range of the
maximum capacity. If the zeroed value is greater than ±2%
of the maximum capacity, then the software displays
a respective error message: <Err2>.