59
Custom functions of <Labelling mode> submenu:
Labels quantity
Parameter for declaring number of labels to be printed
on the scale-connected printer.
C labels quantity
Parameter for declaring number of C labels to be printed
on the scale-connected printer.
Automatic C label triggering
For detailed description read section 20.6.1.
20.6.1. Automatic C Label Triggering
Automatic C Label Triggering function allows to trigger printout of C label,
to do it you must define
<Mode>
and
<Threshold>
parameters.
Procedure:
•
Enter
<Working modes>
submenu and select respective working mode.
•
Go to
<Labelling mode / Automatic C label triggering / Mode>
parameter and set respective option, where:
None
Manual
printout of C label *, performed upon pressing either
or
button.
Mass
Automatic printout of C label, triggered upon exceeding of the total mass value
of the single labels, set in
<Threshold>
parameter.
Number
Automatic printout of C label, triggered upon exceeding single labels quantity,
set in
<Threshold>
parameter.
*)
Manual printout of C labels is carried out using one of the two below
programmable buttons:
Printout with zeroing (weighings qty. and total mass values are zeroed).
Printout without zeroing (weighings qty. and total mass values are not zeroed).
In case of automatic printout of C labels, counter zeroing
function is always on (weighings qty. and total mass values
are always zeroed).
•
To confirm introduced modifications, press
key and go to
<Threshold>
parameter,
<Threshold>
edit box opens.
•
Set the value that is to trigger C label printout, mind that:
−
in case of
<Mode>
parameter set to
<Mass>
value, you must provide
total mass value, upon obtaining of which you want the C label
printout to be triggered,