background image

Start up Guide

Ultra-microbalances:

• 

UYA 4Y PLUS

• 

UYA 4Y

• 

UYA 4Y.F.A PLUS

• 

UYA 4Y.F.A

Microbalances:

• 

MYA 4Y PLUS

• 

MYA 4Y

• 

MYA 4Y.P PLUS

• 

MYA 4Y.P

• 

MYA 4Y.F.A PLUS

• 

MYA 4Y.F1 PLUS

• 

MYA 4Y.F.A

• 

MYA 4Y.F1

Ultra-microbalances

and Microbalances

IMMB-01-02-11-21-EN

Summary of Contents for MYA 4Y

Page 1: ...icrobalances UYA 4Y PLUS UYA 4Y UYA 4Y F A PLUS UYA 4Y F A Microbalances MYA 4Y PLUS MYA 4Y MYA 4Y P PLUS MYA 4Y P MYA 4Y F A PLUS MYA 4Y F1 PLUS MYA 4Y F A MYA 4Y F1 Ultra microbalances and Microbalances IMMB 01 02 11 21 EN ...

Page 2: ... models MYA 4Y PLUS Ultra microbalance 1 Terminal 1 Weighing pan 1 Weighing pan shield 1 Glass weighing chamber lid 1 Microbalance 1 Terminal 1 Weighing pan 1 Weighing pan shield 1 Glass weighing chamber lid 1 Power supply 1 RS232 cable 1 Fabric dust cover 1 Anti draft shield 1 Tweezers 1 Brush 1 Power supply 1 RS232 cable 1 Fabric dust cover 1 Tweezers 1 Brush 1 ...

Page 3: ...ghing chamber lid 1 For models MYA 4Y P PLUS Microbalance 1 Terminal 1 Weighing pan 1 Weighing pan shield 1 Glass vessel 1 Evaporation ring 1 Glass lid with opening 1 Anti draft shield 1 Power supply 1 RS232 cable 1 Fabric dust cover 1 Tweezers 1 Brush 1 Power supply 1 RS232 cable 1 Fabric dust cover 1 Tweezers 1 Brush 1 Glass weighing chamber lid 1 Power supply 1 Additional glass lid 1 RS232 cabl...

Page 4: ...ssel 1 Evaporation ring 1 Glass weighing chamber lid 1 Power supply 1 Additional glass lid 1 Fabric dust cover 1 RS232 cable 1 Glass lid with opening 1 Power supply 1 RS232 cable 1 Fabric dust cover 1 Terminal 1 Filter weighing pan 1 Weighing pan 1 Anti draft shield 1 Centring ring 1 Tweezers 1 Glass lid 1 Brush 1 Tweezers 1 Ultra microbalance 1 Brush 1 ...

Page 5: ...RS232 cable 1 Fabric dust cover 1 Weighing pan 1 Centring ring 1 Power supply 1 RS232 cable 1 Fabric dust cover 1 Tweezers 1 Brush 1 Anti draft shield 1 Tweezers 1 Glass lid 1 Brush 1 Tweezers 1 Terminal 1 Brush 1 Filter weighing pan 1 Microbalance 1 Weighing pan 1 Centring ring 1 Glass lid 1 Terminal 1 Filter weighing pan 1 Weighing pan 1 Centring ring 1 Glass lid 1 Ultra microbalance 1 Microbala...

Page 6: ...er weighing pan 1 Weighing pan 1 Centring ring 1 Microbalance 1 Terminal 1 Power supply 1 Filter weighing pan 1 Weighing pan 1 Centring ring 1 Microbalance 1 RS232 cable 1 Fabric dust cover 1 Tweezers 1 Brush 1 RS232 cable 1 Fabric dust cover 1 Tweezers 1 Brush 1 The plug type may vary by country ...

Page 7: ...r to enable the most stable and repeatable measurement Avoid air drafts and air movements at the workstation Do not place the balance in a hazardous area Do not weigh explosive or flammable materials Place the balance away from heat sources Avoid exposing the balance to the sunlight Make sure that the balance is placed on an even surface Avoid exposing the balance to a mag netic field Do not weigh...

Page 8: ...ON 4 1 Transport lock removal Prior to balance assembly remove the transport lock 5 1 Weighing chamber components assembly 1 1 2 2 3 3 4 5 COMPONENTS ASSEMBLY For models UYA 4Y PLUS MYA 4Y PLUS UYA 4Y MYA 4Y For models MYA 4Y P PLUS MYA 4Y P ...

Page 9: ...5 6 1 2 3 For models UYA 4Y F PLUS MYA 4Y F PLUS UYA 4Y F MYA 4Y F 5 2 Connecting the terminal DC 13 5 16V MAIN DISPLAY Connect the terminal to MAIN DISPLAY connector ...

Page 10: ... adapter to DC connector located at the back of the device Connect the power adapter to the mains 1 2 3 Place the device at the workstation wait until it reaches room temperature up to 12 h DC 13 5 16V To switch the device on press ON OFF key Confirm or cancel the start of the automatic adjustment process 6 2 Switching the balance on Automatic adjustment Automatic adjustment ...

Page 11: ...lance levelling for models with automatic levelling system only Weighing 0 Home Supplementary unit Tare Gross 0 000000 g 0 000000 g Packaging 0 000000 100 Log in Leveling Levelling If your balance features an automatic levelling system it will launch automatically upon turning the device on To initiate the levelling manually follow these steps ...

Page 12: ...he arows shows how to move the balance foots to level the balance Balance has been levelled To close the levelling window press button 6 3 2 Balance levelling for models with semi automatic levelling only Your balance is ready to use Weighing 0 Home Supplementary unit Tare Gross 0 000000 g 0 000000 g Packaging 0 000000 100 Log in Leveling Levelling Leveling Leveling ...

Page 13: ...programmable button Selecting working mode programmable button Proximity sensor Internal adjustment programmable button SETUP function button Editable quick access toolbar Configurable additional information field Weighing result window Status bar Process information field Working modes list Levelling icon balance level state Weighing 0 Home Supplementary unit Tare Gross 0 000000 g 0 000000 g Pack...

Page 14: ...Supplementary unit Tare Gross 0 000000 g 0 000000 g Packaging 0 000000 100 Log in Completed Automatic adjustment Weighing 0 Home Supplementary unit Tare Gross 0 000000 g 0 000129 g Packaging 0 000129 100 SETUP Log in Weighing 0 Home Supplementary unit Tare Gross 0 000000 g 0 000129 g Packaging 100 SETUP Log in Supplementary unit Weighing Tare Gross 0 000000 g 0 Home 0 231185 g Packaging 0 231185 1...

Page 15: ...cal ti Newton N Baht baht Tola tola Mesghal msg User unit 1 User unit 2 8 5 Working modes settings 3 1 2 Press selected button to view the list of available options Press the icon of the current working mode to display the list of available working modes Press information field to access current working mode options Weighing 0 Home Supplementary unit Tare Gross 0 000000 g 0 000000 g Packaging 0 00...

Page 16: ...ers button Users list is displayed select Admin option You have logged in as the Administrator Press Operators button Supplementary unit Weighing Tare Gross 0 000000 g 0 Home 0 000000 g Packaging 0 000000 100 Log in Log in Log out 1 2 Admin Operators 2 Admin Enter password Supplementary unit Weighing Admin Tare Gross 0 000000 g 0 Home 0 000000 g Packaging 0 000000 100 Weighing 0 Home Supplementary...

Page 17: ...Password Name ad Surname Acces level User Account active Yes 3 4 5 6 Edit record 1 Name John Smith Name Name John Smith 1 2 Code Password Name ad Surname Acces level Operator Account active Yes 3 4 5 6 Edit record Code Enter user ID Password Enter user password First and last name Enter user s first and last name Access levels Set respective access level user advanced admin Account status active o...

Page 18: ...ght or left Press information field to access current working mode options Select function that is to be assigned to the choosen sensor Press Buttons button Admin Weighing 0 Home Supplementary unit Tare Gross 0 231185 g 0 000000 g Packaging 0 000000 100 Log in Supplementary unit Tare Gross 0 000000 g 0 000000 g Packaging Weighing Printouts Profile Settings Buttons Information Buttons Soft key 7 Ta...

Page 19: ...10 PERIPHERAL DEVICES CONNECTORS DB15 Stack light Printer Barcode scanner PLC controller RFID reader THB ambient conditions sensor Wi Fi is a registered trademark of Wi Fi Alliance ...

Page 20: ...quid Dry sample leftovers can be removed using either brush or handheld vacuum cleaner Clean components can be dried using soft cloth or dust free paper towel with this the remaining moist will be absorbed Install all the components providing they are completely dry Use soft cloth made of either natural or synthetic fiber exclusively Avoid using cloth made of stiff hard fabric this could cause scr...

Page 21: ... Lift the lid of microbalance weighing chamber Unscrew the draft shield s sleeve counterclockwise and remove it from the weighing chamber Use your finger to press the base of the ring assembly in order to tilt the top edge Grab the top edge and remove the ring assembly through the upper hole of the weighing chamber Using the tweezers carefully remove the weighing pan from the weighing chamber Inst...

Page 22: ...lastic fastener from the weighing chamber using tweezers Press the weighing chamber clamp While pressing the clamp grab the chamber move it towards you and up After cleaning the weighing chamber elements they must be assembled in the reverse order ...

Page 23: ......

Page 24: ...www radwag com ...

Reviews: