21
Manual
–
RadonTec AlphaEx 150/ 200/ 250
4.
9.2
Electrical connection
Danger to life due to electric shock.
Switch off all supply circuits before accessing the
terminals. Switch off the mains fuse, secure it
against being switched on again and visibly attach a
warning sign.
Damage to the unit in the event of a short circuit.
Insulate any wires that are not needed.
It is essential to observe the relevant regulations
for electrical installation and unit assembly, in
Germany in particular DIN VDE 0100 with the
corresponding parts.
Connection
The fan must be connected to the power supply via insulated,
electrical power lines (cables, wires) through the miniature
circuit breaker built into the stationary power supply
network, which interrupts the circuit in the event of a short
circuit or overload.