The degree of protection specified on the type plate
is only guaranteed if the unit is installed as intended
and the cables are properly inserted into the
terminal box.
GOnly connect the unit to a permanently installed
electrical installation with cables of type NYM-O or
NYM-J (3x 1.5 mm² or 5x 1.5 mm²). In addition, a
device for disconnecting from the mains with at
least 3 mm contact opening per pole must be fitted.
Only operate the unit with the voltage and
frequency specified on the type plate.
It is essential to fit a repair switch at the installation
site so that all poles of the unit can be disconnected
from the mains on site during cleaning,
maintenance or repair work. It must be possible to
secure the repair switch against being switched on
again.
Only operate the unit when it is completely
assembled.
A sufficient supply air flow must be ensured.
Modifications and conversions to the unit are not
permitted and release the manufacturer from any
warranty and liability.
Never operate the unit without a protective grille
in the case of free intake (near the floor).
Secure
the unit and piping against foreign bodies being
sucked in. Risk of injury from objects in the
impeller. Do not insert any objects into the unit.