16
Manual
–
AlphaAir Freshbox 100 WiFi
The AlphaAir Freshbox 100 WiFi ventilation system is equipped
with a pre-heating coil. This ensures automatic protection
against overheating of the heating register. The pre-heating
coil is located upstream of the heat exchanger and serves to
protect the heat exchanger against frost.
If the supply air temperature is below -3 °C, the pre-heating
coil automatically ensures that the supply air is heated so that
the average temperature of the extract air downstream of the
heat exchanger is not below +5 °C.
No condensate forms in the AlphaAir Freshbox 100 WiFi with
an enthalpy heat exchanger because the humidity of the
extract air is transferred to the supply air via the enthalpy
membrane.
The shutters open automatically when the fan motors are
switched on and close when they are switched off.
It is possible to connect an additional extract air spigot to
remove air from other rooms, for example the bathroom. The
exhaust air spigot is included in the scope of delivery.