background image

The World’s Leading
Radon Fan Manufaturer

HS Series

Installation

 & Operating

 

Instructions

RadonAway

3 Saber Way    Ward Hill, MA 01835

www.radonaway.com

P/N IN007-REV 

J

9

/1

3

Summary of Contents for HS Series

Page 1: ...The World s Leading Radon Fan Manufaturer HS Series Installation Operating Instructions RadonAway 3 Saber Way Ward Hill MA 01835 www radonaway com P N IN007 REV J 9 13 ...

Page 2: ... open Return unit to the factory for service 6 All wiring must be performed in accordance with the National Fire Protection Association s NFPA National Electrical Code Standard 70 current edition for all commercial and industrial work and state and local building codes All wiring must be performed by a qualified and licensed electrician 7 WARNING In the event that the fan is immersed in water retu...

Page 3: ...s than 32 degrees F or more than 100 degrees F The HS Series Fan is thermally protected such that it will shut off when the internal temperature is above 104 degrees F Thus if the HS Series Fan is idle in an area where the ambient temperature exceeds this shut off it will not restart until the internal temperature falls below 104 degrees F 1 3 ACOUSTICS The HS Series Fan when installed properly op...

Page 4: ...densation can result in system failure and damage the HS Series Fan Condensation is formed in the piping of a mitigation system when the air in the piping is chilled below its dew point This can occur at points where the system piping goes through unheated space such as an attic garage or outside The system design must provide a means for water to drain back to a slab hole to remove the condensati...

Page 5: ...Fan plugs into a standard 120V outlet All wiring must be performed in accordance with the National Fire Protection Association s NFPA National Electrical Code Standard 70 current edition for all commercial and industrial work and state and local building codes All wiring must be performed by a qualified and licensed electrician Outdoor installations require the use of a U L listed watertight condu...

Page 6: ... outlet ducting Solvent weld all connections The muffler is normally installed above the roofline at the end of the vent pipe 2 5 OPERATION CHECKS ANNUAL SYSTEM MAINTENANCE ____ Make final operation checks by verifying all connections are tight and leak free ____ Insure the HS Series Fan and all ducting is secure and vibration free ____ Verify system vacuum pressure with Magnehelic Insure vacuum p...

Page 7: ...proximately 18 lbs Size Approximately 15 W x 13 H x 8 D Minimum recommended inlet ducting greater diameter may always be used HS3000 HS5000 2 0 PVC Pipe HS2000 Main feeder line of 3 0 or greater PVC Pipe Branch lines if 3 or more may be 2 0 PVC Pipe Outlet ducting 2 0 PVC Storage temperature range 32 100 degrees F Thermally protected Locked rotor protection Internal Condensate Bypass ...

Page 8: ...r attempted by others or if the unit has been abused or misused Warranty does not include damage in shipment unless the damage is due to the negligence of RadonAway RadonAway is not responsible for installation removal or delivery costs associated with this Warranty EXCEPT AS STATED ABOVE THE HS SERIES FANS ARE PROVIDED WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING WITHOUT LIMIT...