Enter the Level Three Pass Code
(9898)
.
The display shows the first of the three Commission Menus.
Press
YES
twice to page to Commission Menu Three.
Press 3 to enter Network options.
Unlock the memory using the Memory Lock Switch. The memory must be locked at the end of
the programming session. The panel will not allow a reset unless the memory is locked.
Press 3. The panel displays Network Menu One.
Panel network - address number = ?
Figure 6: Network Menu One
Enter the Network address for the Master Panel. This is a number from one to 20.
Note: In messages on the LCD, the panel software will identify the first slave panel as
Slave CPU 1
,
the second slave panel as
Slave CPU 2
, and so on.
Avoid confusion between network addresses and panel identifications by giving the master panel
a unique identification number (i.e. 10).
The panel displays Network Menu Two.
Quantity of slave processors = ?
Figure 7: Network Menu Two
Enter the number of slave processors (1 to 3 in a shared zone network). The panel displays
Network Menu Three
Slave CPU 1 is at network addr ?
Figure 8: Network Menu Three
Enter the address for the first slave CPU. Network Menu Three will change to prompt for the
address of the next slave CPU until the number of slave processors entered in Network Menu
Two are identified.
The panel then displays Network Menu Four.
Use modem [FALSE] ?
Figure 9: Network Menu Four
Enter
YES
if the master panel is NOT connected to a modem. If a modem is connected to Port
B or Port C of the master panel, press
CHANGE
to alter the statement to TRUE and press
ENTER
.
The panel displays Network Menu Five.
Share zones [TRUE] ?
Figure 10: Network Menu Five
Press
YES
.
The panel displays Network Menu Six.