D2112/D2112E Terminal Quick Reference
Radionics, Inc., 1800 Abbott Street
Radionics, 1 Park Gate Close, Bredbury
Salinas, California 93901
Stockport, Cheshire, SK6 2SZ, England
Customer Service: (800) 538-5807
Technical Support: (061) 494 0851
™
The Radionics logo is a registered trademark of Radionics, Inc., Salinas, CA, U.S.A. ©1994 Radionics, Inc., Salinas, CA, U.S.A. All rights reserved
Terminal
Description
1,2
AC Input
Connect 16.5 VAC, 25 VA transformer for primary power
source.
3
Earth Ground
Connect to earth ground. A cold water pipe or grounding rod is
preferred. Do not connect to telephone or electrical ground.
4
Battery Positive
Connect Positive terminal of 4.0 to 7.0 Ah battery to this
terminal.
5
Battery Negative
Connect Negative terminal of 4.0 to 7.0 Ah battery to this
terminal.
6
Alarm Output Positive
Supplies 1.5 Amps at 10.2 to 13.9 VDC for alarm output. This
terminal provides a constant output. Negative is switched.
7
Alarm Output Negative
Negative terminal for alarm output. This terminal switches for
pulsed or steady alarm output.
8
Keypad Data
Data for Keypads
9
Auxiliary Power Positive
Supplies 350mA at 10.2 to 13.9 VDC for auxiliary power,
keypads, and relay outputs .
10
Common
Common for Auxiliary Power and Relay Drivers
11
External Relay 1
Connect D133 Relay for Form C Dry Contact
12
External Relay 2
Connect D133 Relay for Form C Dry Contact
13
D2112 Positive Point 1
Not used on D2112E
D2112: Positive power for Point 1. Switched for sensor reset.
Use for approved two wire smoke or glass break detectors.
14
D2112: Negative Point 1
D2112E: Input Point 1
D2112: Negative power for Point 1
D2112E: Input for Point 1
15
Common
Common for Points 1 and 2
16
Input Point 2
Input for Point 2
17
Input Point 3
Input for Point 3
18
Common
Common for Points 3 and 4
19
Input Point 4
Input for Point 4
20
Input Point 5
Positve for Point 5
21
Common
Common for Points 5 and 6
22
Input Point 6
Input for Point 6
23
D2112: Point 7
D2112E: Not Used
D2112: Input for Point 7. No EOL Resistor
D2112E: Not Used
24
Common
Common for Points 7 and 8
25
D2112: Point 8
D2112E: Not Used
D2112: Input for Point 8. No EOL Resistor
D2112E: Not Used
26
T1
Tip of phone line to premises phone
27
T
Tip of incoming phone line
28
R
Ring of incoming phone line
29
R1
Ring of phone line to premises phone