(1) Low-power precharge: When it is detected that the voltage of a single cell of the battery is

lower than 3.0V, a small current is used to activate the battery to restore the battery

capacity.

(2) Fast charge: When it is detected that the voltage of a single cell of the battery is higher than

3.0V and lower than 4.16V, 1.5A is used to charge the battery.

(3) Trickle charging: When it is detected that the voltage of a single cell of the battery is higher

than 4.16V, 0.8A is used to charge the battery to make the battery fully charged and avoid

overcharging.

(4) Temperature control: When it is detected that the board temperature is higher than 75

degrees Celsius, the charging current will be reduced to 2/3 of the predetermined current to

lower the board temperature, and when it is detected that the board temperature is lower

than 70 degrees Celsius, predetermined current will be restored to charge the battery.

(5) Power supply protection: When it is detected that the power supply voltage drops to 3.7V,

the current current is set to a predetermined current to adapt to various charging heads of

different specifications.

(6) Balance charging: When the battery voltage is charged to 4.16V, if it is detected that the

voltages of the two batteries are not equal, the balance charging is turned on to ensure that

the battery voltages are consistent.

(7) Charging alarm: When there is no current detected for a long time, charging will be

automatically stopped, and the red LED will flash to indicate abnormality.

(8) Charging time: About 40 minutes for a 500mAH 2S battery.

(9) Voltage precision: The full voltage is 4.20V±0.02V.

(10) Charging efficiency: Higher than 82%.

Summary of Contents for CM210

Page 1: ...RadioLink Electronic Ltd www radiolink com 1 CM210 Balance Charger for 2S LiPo battery User Manual Note To ensure the safe use of CM210 please read this manual carefully before use ...

Page 2: ...RadioLink Electronic Ltd www radiolink com 2 Contents 1 Safety Precautions 3 2 Functions 4 3 Speficifications 5 4 Instructions for Use 5 5 LED Indicator Status 6 6 Voltage Calibration of CM210 7 ...

Page 3: ...material while in use 8 Do not try to charge non rechargeable dry cells Thanks for choosing RadioLink CM210 balance charger To fully enjoy the benefits of this product and ensure safety please read the manual carefully If any problems found during the operation process either way listed below can be used as online tech support 1 Send mails to after_service radiolink com cn and we will answer your ...

Page 4: ...ed to 2 3 of the predetermined current to lower the board temperature and when it is detected that the board temperature is lower than 70 degrees Celsius predetermined current will be restored to charge the battery 5 Power supply protection When it is detected that the power supply voltage drops to 3 7V the current current is set to a predetermined current to adapt to various charging heads of dif...

Page 5: ... into the Type C input port of the CM210 charger as shown in the picture below and then connect the other end of the USB cable to power supply equipment such as power bank computer mobile phone adapter etc After the right connection the red LED indicator will be always on 2 Insert the balance port of the standard 2S lithium battery of A560 into the charging port of CM210 as shown in the picture be...

Page 6: ...ll green LEDs will flash once when the charger is powered on indicating that the calibration has been done Voltage calibration has already finished by factory default Red LED is always on When the charger is powered on and no battery is connected the red LED is always on indicating battery needs to be connected Red LED flashes during charging The charger detects abnormality Please reconnect batter...

Page 7: ... and lower than 8 4V All four green LEDs are always on The battery is fully charged 6 Voltage Calibration of CM210 Three power supplies are required Two 5V power supplies at the battery end with 0 1A current When the battery end is connected turn on the battery end power supply The voltage of the charging end power supply is set to 5V with 3A current When the power supply end is connected turn on ...

Reviews: