Table 9
– Timing numbers, configuration commands with arguments but no response data
Command Parameter
MBUS3
MBUS4
Comment
Any
T
BYTE
Varies with UART datarate
Any
T
UART_BYTE
Varies with UART datarate
B,K
T
WAIT_1
3.9 ms / 7.8ms
~50us
B,K
T
WAIT_2
45 ms
55 ms
In this period the internal flash (non-volatile memory)
is programmed.
Do not reset, turn the module off,
or allow any power supply dips in this period as
it may cause permanent error in the Flash
configuration memory. After the last command
parameter byte the host should wait for the ‘>’
prompt before any further action is done to
ensure correct re-configuration.