Radio Systems, Inc.
•
601 Heron Drive
•
Logan Twp., New Jersey 08085
(856) 467-8000
•
Fax (856) 467-3044
•
www.studiohub.com
For Assy:
TIE24-8,
TIE12-8
Rev: 01/05
St Model TIE24-8 & Model TIE12-8
Engineered for Inter-Studio Tie Lines
General
Tie Hubs provide multi-pair inter-studio connectivity by
splaying out CAT-5 25 pair cable to individual RJ-45
connectors via a 50 pin RJ-21 mass connector. Depending on
the model selected, either 2 or 4 CAT-5 pairs are connected
to each RJ-45 connector. Double the density is achieved if
only 2 pairs (4 wires) are required to connect to each RJ-45.
Generally, 2 pair is sufficient to support StudioHub analog
and digital audio circuits. All 4 pairs (8 wires) are needed to
support KVM and other special multi-wire equipment circuits.
DC Power
DC Tie-Line hub models allow St DC-Link +/-
15 volt power to be added on the far-side of the link to power
local StudioHub powered peripherals (such as headphone
amps and MatchJacks). An external St DC power
supply must be utilized. Jumpers and re-settable fuses for each
RJ-45 channel allow the DC power to be added. The power
option is only available on 2-pair per RJ-45 Hub models.
Grounding Information
RJ-45 connector shields may be optionally connected to the
chassis ground by inserting a jumper. A jumper is also
provided to allow the unused CAT-5 25
th
pair to be
connected to this common shield bus. In addition, on
powered models, the power supply shield may be jumper
connected to the RJ-45 shields.
Name
TIE24-8 / TIE12-8
Mount
Full Hub / Half Hub
Channels
12 / 12
CAT-5 Pairs
4 (all)
Power Link
no
Connectors
RJ-21, 2 RJ-45 & 110
Versions
Full Hub/Half Hub/Board Only
Product Key
Model TIE24-8 pictured
also available as
Ω
hub 12 channel - model TIE12-8
2 RJ-45 in parallel to
bridge inputs or outputs
10 pin 110-style
connector provides
access to all 4 CAT-5
pairs and cable shield
RJ-21 connects 25-pair
CAT-5 cable carrying six
4-pair circuits. Four 25-
pair RJ-21 cables
required to connect all
24 4-pair Hub circuits.
Insert jumper to connect
the RJ-45 shields to
chassis ground
8
7
6
5
4
3
2
1
Shield
RJ- 45
Hub
Chassis
Ground
JU2
x 12
or 6
8
7
6
5
4
3
2
1
RJ- 45
110 Connector
J6
J3-1
JU1
J4-1
Unused
Pair (25)
J1
Shield
RJ-21
Blu/Wht G
Wht/Org L+
Org/Wht L-
Wht/Grn R+
Grn/Wht R-
Wht/Brn - 15V
Brn/Wht + 15V
Slt/Wht Shd
Wht/Slt Shd
Wht/Blu n/c
Connects 25
th
CAT-5 pair
to shields of the RJ-45 s
bn