Digital BUS-WATCH
®
R1001 / R4001
TROUBLESHOOTING GUIDE (Continued)
PROBLEM
POSSIBLE CAUSE
CORRECTION
Wrong Network Cable
Type
Use Crossover Cable
(REI P/N 530068)
DVR IP Settings not
Configured Correctly
Configure Network Settings
Ethernet Connection Not
Working
PC IP Settings not
Configured Correctly
Configure Network Settings
(Contact you System
Administrator or IT
Department)
USB Connection Not
Working
DVR in Wrong USB Mode
Change USB Mode
No Video Out
Camera(s) Not Connected
Verify Camera Connection
Audio Recording Disabled
Enable Audio
See Figure 64
No Audio Out
Volume Turned All The
Way Down.
Use UP ARROW on
Remote Control to Increase
Volume
Page 95 of 96
Radio Engineering Industries, Inc.
640370 -- Rev 0 -- 8/17/2007