For TKAN 80 Integra and TKAN 100 Integra, it is not recommended to install the
dedusting valves and they are not pre-integrated.
For TKAN 150 Integra a 10l tank and two pulse valves are delivered.
For TKAN 200 Integra, TKAN 250 Integra, and TKAN 300 Integra a 24k tank and a four
pulse valves are delivered.
Operation principle:
The operation principle of unit C is based on rapid ejection of compressed air through
holes on the door to clean smoke pipes from soot properly. Automatic initiation of pulse valves
is pre-set and is initiated one by one at certain time intervals. The micro switch is also installed
on the upper door that will, in case of opening the upper door, abort dedusting function
instantly. Once the upper door is closed, the micro switch is activated and the automatic
dedusting initiates. The air tank and safety valve hasve to be certified. The user of the
equipment under pressure is obliged to control the tank and safety valve, regulated by the
examination and inspection rulebook for the equipment under pressure.
3.5. Installing multi cyclone
Models TKAN 80 Integra and TKAN 100 Integra do not have the pre-integrated
cyclonebut they have the fan on the chimney.
In order to reduce the emission of dust particles from flue gases, it is recommended to
install the multi cyclone and the centrifugal fan. By installing it, it is simultaneously possible
to reduce the required height of the chimney. With the multi cyclone and the fan, it is necessary
to install boiler regulation as well. The multi cyclone represents a group of many cyclones
smaller in diameterthat are set in the mutual case.
Flue gases are introduced tangentially near the top of the cylindrical part of the cyclone,
and because of the action of the centrifugal force, the outcome is the separation of particles
from gas that reach the cyclone‘s walls. By the action of weight force, separated particles
spirally travel downwards along the cone-shaped part of the cyclone into the container.
Cleansed gas’s current spirally flows out through the submerged pipe of the cyclone into the
atmosphere or pipe system.
Picture 7. Schematic diagram of a multicyclone