Radiance instruments RT616 Series Product Manual Download Page 1

RADIANCE 
INSTRUMENTS 
LTD. 

PRODUCT MANUAL 

REV.: 4

 

PRODUCT  Water Resistant Digital Pocket Thermometer 

7 AUG 2013 

MODEL 

RT616 

PAGE 1 of 2 

 

>>>>> All rights reserved <<<<< 

FEATURES: 

 

IP67 water resistant 

 

C/

F exchangeable 

 

Data hold function 

 

Maximum and minimum reading memory 

 

Stainless steel probe 

 

Low battery indication 

 

Temperature calibration 

 

CE, NSF and RoHS compliant   

 

 

SPECIFICATION:

 

 

 RT616-150 

 RT616-200 

 RT616-300 

Measuring range 

-40~150

C / -40~302

F  -50~200

C / -58~392

F  -50~300

C / -58~572

Accuracy 

±0.5

C in -10 ~ 100

C , ±1.5

C rest range 

±0.9

F in 14 ~ 212

F, ±2.7

F rest range 

±0.5

C in -10 ~ 100

C , 

±2

C in 200 ~ 300

±1.5

C rest range 

±0.9

F in 14 ~ 212

±3.6

F in 392 ~ 572

±2.7

F rest range 

Display resolution 

0.1

 

Display reading update  1 second 
Temperature response  About 8 seconds from 25 to 100

Automatic power off 

After idle for 1 hour 

Water resistant rating 

IP67 

Battery 

3 volt, type CR2032 or equivalent x 1 piece (included) 

Battery life 

About 5,700 hours in continuous operation 

Ambient temperature 

0~50

C / 32~122

Product size 

155(L) x 26(

) mm 

Probe size 

73(L) x 2.5(Ф) mm 

Reduced probe tip size  17(L) x 1.6(

) mm 

NA 

17(L) x 2.0(

) mm 

   

 

OPERATION 

BATTERY INSTALLATION 

1.

 

Open the battery cap. 

2.

 

Install the battery with correct polar positioning. 

3.

 

Close the battery cap tightly.   

 

POWER ON AND OFF 

Remove the probe cover to switch on the thermometer. Insert the probe cover to switch off. 

 

SELECT TEMPERATURE UNIT 

Open the battery cover and switch 

C or 

F under the battery. 

 

TEMPERATURE MEASUREMENT 

Probe into test substance about 25mm / 1'' minimum and get the reading when it becomes stable. 

 

 

 

 

 

DATA HOLD FUNCTION 

1.  Press [HOLD] to retain display reading, 

C or 

F flashing. 

2.  Press [HOLD] again to display normally. 

 

MAXIMUM AND MINIMUM READING MEMORY   

1.

 

Press [MAX/MIN] to display maximum recorded reading. 

2.

 

Press the button again to display minimum recorded reading. 

3.

 

Press the button once more to display normally. 

4.

 

To reset the memory, Press and hold the button for 3 seconds until a bar “---.-” is displayed. 

5.

 

Always reset the memory once before taking new readings. 

 

 

 

TEMPERATURE CALIBRATION 

1.

 

Press [MAX/MIN] and [HOLD] buttons together and hold about 5 seconds until display and flash “CAL” 2 

seconds, then enter into the calibration mode. 

2.

 

Press [MAX/MIN] or [HOLD] to set the temperature error.   

3.

 

Press [MAX/MIN] and [HOLD] buttons together again to confirm the setting and exit the calibration mode. 

*The adjustable temperature error range is -2.2~+2.2

C (-4~+4

F). 

*You can set the temperature error in 0

C or any temperature point. 