A P P E N D I C E S
106
Series 8000™ O&M Manual
Appendix 4:
Model 8250 Drive Cabinet
Also see section 2
”
A-4.1
Operating Environment, Power
Temperature:
-40 to 50°C
Low-temp package necessary below -10°C.
Humidity:
100% condensing
Electrical:
200 and 400 Volt Class, 50
–
60 Hz, 5-wire WYE
Electrical-current requirements determined by
motor horsepower.
A-4.2
Mechanical
Height: 36” (legs 18”H)
Width: 30”
Depth: 10”
Weight: 100 lbs.
Motor size: 1
–
5 HP standard. Larger sizes available.
A-4.3
I/O Controller Location
•
Using the Model 8200 with a Radeus Labs Model 8250 drive cabinet:
The I/O controller (IOC) is mounted in the drive cabinet. The
only connections to the ACU are an Ethernet cable and the
drive-enable line.
•
Using the Model 8200 with a legacy GD/Vertex 7150 drive cabinet:
The I/O controller is mounted inside the ACU chassis. All
control lines must run from the legacy cabinet to the ACU.