34
EN
Maximum cable length for connecting external signal transducers
to E1 or E2 (e.g. Venetian blind switches or Venetian blind buttons /
external sensors etc.)
The maximum cable length for connecting external signal transducers
to E1 or E2 must be 15 metres.
Installation materials
The Troll Comfort DuoFern is designed for flush-mounted installation.
We recommend installation in a deep 58 mm flush-mounted box or in
an electronic socket.
Stripping length
6 mm
All leads must be stripped to 6 mm.
8.1 Important information prior to the electrical
i