28. Technical Specifications
External dimensions control unit
[ 1 ]
:
50 x 50 x 12 mm (according to DIN 49075)
Nominal voltage:
230 V / 50 Hz; 230 V / 60 Hz
Max. switching capacity:
8 (4) A µ (Type 1B)
Standby consumption:
< 0.4 W
Extension inputs:
2 (E1 and E2)
Connection diameter:
1.5 mm²
Installation depth:
32 mm
Permissible ambient temperature:
0 to 40°C
Data retention:
permanent
Protection class:
II (only for use in dry areas)
Transmission frequency:
434.5 MHz
Transmission power:
max. 10 mW
Range:
indoors approx. 30 m * / outdoors approx. 100 m
* depending on the building structure
29. Factory settings
Automatic: On
Automatic time:
On
Automatic dawn function:
Off
Automatic dusk function:
Off
Automated solar function:
Off
Sunshine position:
50 %
Motor running time:
150 seconds
Ventilation position:
Off / 80 %
Blinds mode:
Off, tilting time: = 1.50 seconds
■
Auto tilt to:
- Sunshine position:
Off
- Ventilation position:
Off
■
Auto tilt after:
- Moving to a target position:
On
- Manual stop in direction "Down"
On
■
Standard slat position:
0 %
■
Motor dead time:
Off
Jog mode:
Off