25
EN
Maximum cable length for connecting external signal transducers
to E1 or E2
The maximum cable length for connecting external signal transducers
to E1 or E2 must be 15 metres.
Installation materials
The Troll Standard is designed for flush-mounted installation. We
recommend installation in a deep 58 mm flush-mounted box or in an
electronic socket.
Stripping length
6 mm
All leads must be stripped to 6 mm.
8.1 Important information prior to the electrical
i
8.2 Electrical connection
1.
Ensure the mains is disconnected and check whether the mains power
cables are current-free.
2.
Securely lay all connecting cables right into the flush-mounted box.
3.
Remove the insulation on all leads down to 6 mm in length and
connect them according to the connection diagram on the following
pages.
4.
After the electrical connection, the installation of the Troll Standard into
the flush-mounted box is carried out, see page 27.