RADEMACHER DuoFern Universal 9470-1 Instruction Manual Download Page 1

VBD 623-3 (12.20)

Item no. 3514 02 61

EN

DuoFern Universal Actuator 9470-1 (1-channel)

Instruction manual for the electrical connection and for commissioning

Type: 9470-1

Summary of Contents for DuoFern Universal 9470-1

Page 1: ...VBD 623 3 12 20 Item no 3514 02 61 EN DuoFern Universal Actuator 9470 1 1 channel Instruction manual for the electrical connection and for commissioning Type 9470 1...

Page 2: ...ou for the trust you have placed in us RADEMACHER products have been developed with the greatest possible convenience in mind Having applied uncompromising quality standards and thorough testing we ar...

Page 3: ...iption of the functions and parameters 15 6 Technical specifications 17 7 Safety instructions 20 7 1 Intended use 20 7 2 Improper use 21 7 3 Expert knowledge required by the installer 22 8 Connecting...

Page 4: ...4 EN Contents i 10 Deleting all settings reset 30 11 Dismantling 30 12 Simplified EU declaration of conformity 31 13 Warranty terms and conditions 31...

Page 5: ...tion manuals of the accessories if available as well as the instructions of the respective con nected appliance This manual is part of the product Please store it in an easily accessible place When pa...

Page 6: ...angerous situation 2 1 Levels of danger and signal words DANGER This hazard will lead to serious injury or death if not avoided WARNING WARNING This hazard may result in serious injury or death if not...

Page 7: ...7 EN 2 2 Symbols and depictions used Depiction Description 1 Procedures 2 Itemisation 1 or a Lists i Further useful information Please read the respective manual i...

Page 8: ...patible products WR ConfigTool RADEMACHERsoftwareforprogrammingtheDuoFernManual Control incl automatic software updates for the DuoFern Manual Control HomePilot The HomePilot is a central controller u...

Page 9: ...9 EN i 3 Included in delivery Included in delivery a 1 x DuoFern Universal Actuator 9470 1 incl antenna b 1 x instruction manual not illustrated a...

Page 10: ...2 1 4 Pos Symbol Description 1 Control input 230V 50 Hz on off Connection of an external switch button for manual control on site 2 Relay contact K Connection of an electrical appliance 3 Neutral con...

Page 11: ...light status display green flashing constantly lit up brief flashing Connection is active Connection or disconnection was successful Control command received red flashing or permanently lit up Disconn...

Page 12: ...eration on site Installation and electrical connection The DuoFern Universal Actuator 9470 1 is designed for flush mounting The electrical connection is carried out by means of clamping the connecting...

Page 13: ...e range Factory setting A B C D E F G 1 Manual operation On Off Dim 2 Unit light mode Unit light mode Light mode 3 Manual mode on off on off off 4 Automatic timer on off on off on 5 Random function 6...

Page 14: ...Standard DuoFernWall Controller Function Value range Factory setting A B C D E F G 12 Connectivity test 13 Connect with radio code 14 Reset via radio 3 stage 15 Single button operation 16 Stairwell f...

Page 15: ...f On Dawn function On Off Automatic dusk function Off On Random function presence simulation The DuoFern Universal Actuator 9470 1 can process random functionswitchingcommands Ifaswitchingcommandisrec...

Page 16: ...irway function on off When the stairway function is active the DuoFern Universal Actuator 9470 1 will switch off the controlled device again after the set stairway time An advanced switch off warning...

Page 17: ...for an external manual switch button on site Input voltage 230 V Ri 200 kW Relay output load contact K Switching voltage 230 V 50 Hz Maximum switching capacity Ohmic load e g bulbs 16 A 3600 W Inducti...

Page 18: ...ations Improper use can lead to serious injuries or property damage Small contact distance not suitable for disconnecting the device Do not use the DuoFern Universal Actuator 9470 1 to discon nect the...

Page 19: ...tion Permissible ambient temperature range 20 C to 55 C Dimensions W x H x D 48 7 x 45 7 x 19 8 mm Connecting terminals Spring resistance connecting terminals 0 1 mm2 1 5 mm2 for solid conductors 6 Te...

Page 20: ...within the permissible load limits see Technical Specifications The DuoFern Universal Actuator 9470 1 is suitable for connect ing the mains voltage and extra low voltage ELV with basic insulation Oper...

Page 21: ...xtra low voltage SELV Never use the radio system e g DuoFern radio system and its components for the remote control of devices and systems with increased safety relevant requirements or where there is...

Page 22: ...tuator 9470 1 8 1 Safety instructions for the electrical connection DANGER There is a risk of fatal electric shock when touching electri cal components All connection and installation work must only b...

Page 23: ...observe the details in the Technical Specifications see page 18 ATTENTION A defective antenna can lead to malfunctions or failure of the DuoFern Universal Actuator 9470 1 The antenna lead must not be...

Page 24: ...0 1 is intended for flush mounting We recommend installation in a deep 58 mm flush mounted box or in an electronic socket Length of insulation stripped 9 mm All leads must be stripped to 9 mm 8 2 Impo...

Page 25: ...1 3 Remove the insulation on all leads as specified above and con nect them according to the following connection diagram 4 InserttheDuoFernUniversalActuator9470 1intotheflush mount ed box and lay the...

Page 26: ...ermany N L PE 230 V 50 Hz N PE L Appliance Control input E Relay contact K Power supply L i External switch button Neutral conduc tor N Required connecting cable and cable cross section for con nectin...

Page 27: ...K L N L 1 2 N 230 V 50 Hz L Relay contact K 230 V 50 Hz Toggle switch Control input E Relay contact K Appliance Installation with toggle switches We recommend replacing the toggle switch with several...

Page 28: ...e DuoFern Universal Actuator 9470 1 3 The DuoFern Universal Actuator 9470 1 then transmits either a log on or log off signal Log on log off mode remains active for 120 seconds 4 If the log on log off...

Page 29: ...to the actuator after installation You will find the radio code on the enclosed label and on the rear side of the DuoFern Universal Actuator 9470 1 i Please note that the use of the radio code is limi...

Page 30: ...reset can be carried out to reset the DuoFern Universal Actuator 9470 1 to the default factory settings 11 Dismantling DANGER There is a risk of fatal electric shock when touching electri cal componen...

Page 31: ...24 monthwar ranty for new systems that have been installed in compliance with the installation instructions All construction faults material de fects and manufacturing defects shall be covered by the...

Page 32: ...by replacement of the affected parts or by supplying a new replacement unit or one to the same value There is no general extension of the original warranty period by delivery of a replacement or by r...