7. Technical specifications
Troll Comfort
Mains connection [ L / N ]
Mains supply
voltage:
230 V / 50 Hz, 60 Hz
Consumption:
Standby: < 0.3 W
2 x extension inputs [ E1 / E2 ] - configurable
Connection of external signal transducers (Venetian blind button/
environmental sensor etc.)
Input voltage:
230 V / 50 Hz
(Ri = 200 k
W)
Maximum cable length:
15 metres
Rotation direction [
s
/
t
]
Switching voltage:
230 V / 50 Hz
Switching capacity:
M
8 (4) A µ (Type 1B)
Personal injury and property damage may occur if the Troll Comfort
is used to disconnect the connected appliance.
◆
Small contact distance (µ), not suitable for disconnecting the device.
◆
Do not use the Troll Comfort to disconnect the
connected appliance.