77
EN
20. Removing the belt in the event of unit failure
In the event that the RolloTron Comfort DuoFern unit fails
and the motor no longer runs, you can use the disengaging
bracket provided in order to fully remove the belt from the
belt winder unit, without the need for cutting it.
1.
Remove the mains plug from the socket.
2.
Dismantle the RolloTron Comfort DuoFern as previously
demonstrated on page 75.
3.
Release the drive with the help of the supplied disengaging
bracket. A small amount of resistance must be overcome
when pressing.
4.
Maintain pressure on the disengaging bracket and pull the
belt out of the RolloTron as far as possible.
RolloTron
Comfort
DuoFern
RolloTron
Comfort
DuoFern
Plus
i
Drive release
Storage bay
Drive release
WARNING!
WARNING!
There is a risk of injury as the roller shutters may slam
shut or fall in an uncontrolled manner.
◆
Secure the roller shutters from falling.
◆
Hold on to the belt tightly to stop the roller shutters
from slamming shut or falling in an uncontrolled
manner.
◆
Get a second person to help you unlatch the unit.
5.
Release the belt from the fastening hook and pull it out
completely from the RolloTron.
6.
Replace the disengaging bracket in its holder.