Alarm management
The average values of parameters listed in the table (Watched values) are continuously monitored.
When any of them exceeds the respective threshold, the selected action(s) is(are) invoked.
NOTE:
At least 10 values have to be included on average before it is checked for the possible
alarm. Since different values are sampled over different periods, different times are required to obtain
correct values:
Ucc, Temp – approx. 10 sec. after booting
PWR, VSWR - approx. 10 sec. after booting and after the first transmission
Others – approx. 200 sec. of respective communication
Threshold
List box: Default, Manual
Default = Default
Default
– Default (recommended) values are set and can not be edited.
Manual
– Thresholds can be set manually. However there are individual min. and max. threshold
values for each item. When your settings are out of the possible interval, the web interface will
give you a warning and display the possible values.
SNMP Trap
When ticked, the SNMP trap message is sent both when a parameter value exceeds the alarm
threshold and when it returns back within its "normal" range. Remember to set the IP destination
address(es) and port(s) for SNMP trap messages in Settings/Device/SNMP.
When even one SNMP trap tick box is reconfigured in Alarm table, all SNMP traps for active
alarms (out of thresholds) are re-sent with exception of the HW alarm input.
105
© RACOM s.r.o. – RipEX Radio modem & Router
Advanced Configuration
Summary of Contents for RipEX
Page 2: ......