Time zone
Time zone to represent unit internal time. All the unit timestamps are displayed using this time zone.
Changing the time zone does not affect unit internal records – they are always recorded using UTC
time zone.
NTP servers
Multiple NTP servers can be configured to get more precise time synchronization or to have a
backup solution in case of an individual NTP server unavailability. Maximum number of records in
the list is 32. The unit runs in an “orphan” mode if the
NTP client synchronization source
is set
to “NTP server” and there is no NTP server defined in this list.
7.6.2. Configuration
There are several tools to operate full unit configuration: Backup, Restore, and restore to Factory settings.
Backup
It is a good practice to make a configuration backup into an external file every time the configuration
is changed, to be able to restore the configuration into another unit in case of unit maintenance.
Backup and download
button triggers the web browser Download action. The specific behaviour
depends on your web browser personal settings - whether the configuration backup file is downloaded
to a predefined download folder or the file Download dialog to select destination folder is shown.
The configuration is stored in a text file (.json file type).
The backup configuration has the following limitations:
• The set of configuration data is limited by a user access privileges of the user who performed
the backup. The full configuration backup can only be issued by a user with the Administrator
(role_admin) access privileges. The same user access limit applies when the configuration is
restored (i.e. the full configuration Restore can only be issued by a user with the Administrator
(role_admin) access privileges).
131