09 - MFD CAN Output
The MFD has a CAN output which is present on the two upper 5-way connectors.
Data format: Motorola; Baud rate: 500 kbit/s.
Standard Channels
Data Bytes
ID
1
2
3
4
5
6
7
8
0x500
(1/2)
Units
(3) Trigger_Speed
(4) Trigger_Distance
Unused
0x501
(5) Time_from_Trigger
(6) Peak_Decel
(7) Average_Decel
0x502
Unused
(8) MFDD
(9) Corrected_Dist
Unused
0x503
Unused
(10) Start_Speed
(11) Test_Time
Unused
0x504
Unused
(12) End_Speed
(13) Distance_Travelled
Unused
0x505
Unused
(14) Start_Speed
(15) Test_Time
Unused
0x506
Unused
(16) End_Speed
(17) Distance_Travelled
Unused
0x507
Unused
(18) Target_Distance
(19)
Velocity_atTarget_Dis
Unused
0x508
Unused
(20) Time_To_Complete_Test
Unused
1. Distance units indication, single bit, 0 = Feet; 1 = Meters.
2. Velocity units indication, single bit, 0 = MPH; 1 = KPH.
3. Velocity when brake trigger activated, 0.01 km/h/ mph per bit.
4. Distance travelled from activation of brake trigger, 0.01 m/ft per bit.
5. Time from brake trigger being activated until rest, 0.01 seconds per bit.
https://racelogic.support/01VBOX_Automotive/06Displays/Multi-Function_Display_(MFD)/