X17™

 XFU 3-WAY FIELD-ADJUSTABLE FLOODLIGHT

 

SELECTABLE PHOTOCELL INSTALLATION 

RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install 

and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]

X17 XFU 35/25/15W Knuckle

KNUCKLE MOUNT

IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.

  

RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is 
required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON 
FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. 

WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside. 
WARNING: Do not use an electric generator to test LED fixtures.
WARNING: Min 75°C SUPPLY CONDUCTORS. 

1.  Secure the fixture to a 1/2” NPS hole in the junction box or 

landscape post as shown in 

Fig. 1. 

Seal arm thread using      

Teflon® tape or silicone sealant.

2.  Make appropriate wire connections per NEC in an approved 

enclosure 

(not included)

 see 

Fig. 5.

3.  The 

Knuckle Arm

 allows 180° of vertical aiming adjustment 

depending on the mounting position as shown in 

Fig. 2.

Fig: 1

Fig: 2

Knuckle Arm

Pole

FIELD ADJUSTMENT

Follow instructions below to change fixture 

Power

 (

W

) or 

Color 

Temperature

 (

CCT

) from the factory settings and 

Photocell

 On/Off 

option.

Factory Settings: 4000K and 35W

1.  Remove

 Selector Switch Caps 

by turning counterclockwise

 

using a flat head screwdriver 

(Fig. 3).

2.  Locate the 

Selector Switches

 on the fixture 

(Fig. 4).

3.  Select

 Power 

(

W

) and

 Color Temperature 

(

CCT

)

 by sliding the 

respective switch to the desired value.

4.  Select 

Photocell

 On/Off option by sliding respective switch 

 

to the desired value.

POWER (W) Selector Switch

Photocell Selector Switch

CCT Selector Switch

Selector Switch Caps

Fig: 3

Fig: 4

To ensure weatherproof seal, apply weatherproof silicone sealant 
around the edge of the junction box 

(not supplied)

. This is especially 

important with an uneven wall surface. 

Summary of Contents for X17 XFU

Page 1: ...r to test LED fixtures WARNING Min 75 C SUPPLY CONDUCTORS 1 Secure the fixture to a 1 2 NPS hole in the junction box or landscape post as shown in Fig 1 Seal arm thread using Teflon tape or silicone sealant 2 Make appropriate wire connections per NEC in an approved enclosure not included see Fig 5 3 The Knuckle Arm allows 180 of vertical aiming adjustment depending on the mounting position as show...

Page 2: ...ite Blue fixture lead to the COMMON supply lead 3 Connect the Green Yellow wire from fixture to supply ground Do NOT connect the GROUND of the dimming fixture to the output 4 Connect the purple fixture lead to the DIM V lead 5 Connect the gray fixture lead to the DIM V lead 6 Cap the yellow fixture lead if present Do NOT connect CLEANING MAINTENANCE CAUTION Be sure fixture temperature is cool enou...

Page 3: ...the junction box or landscape post as shown in Fig 1 Seal arm thread using Teflon tape or silicone sealant 2 Make appropriate wire connections per NEC in an approved enclosure not included see Fig 7 3 The Knuckle Arm allows 180 of vertical aiming adjustment depending on the mounting position as shown in Fig 2 Fig 1 Fig 2 Knuckle Arm Pole TRUNNION MOUNT To adjust the angle of the Fixture using the ...

Page 4: ... connect TROUBLESHOOTING 1 Is the fixture grounded properly 2 It is recommended that gloves be worn to avoid injury during installation 3 If any smoke or spark please turn off the power immediately X17 XFU 60 50 30 IN 0921 Note These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation operation or maintenance P 10005...

Page 5: ...dscape post as shown in Fig 1 Seal arm thread using Teflon tape or silicone sealant 2 Make appropriate wire connections per NEC in an approved enclosure not included see Fig 9 3 The Knuckle Arm allows 180 of vertical aiming adjustment depending on the mounting position as shown in Fig 2 TRUNNION MOUNT Trunnion Mount accessory included To Install the Trunnion 1 Remove the pre installed Knuckle Moun...

Page 6: ...o NOT connect the GROUND of the dimming fixture to the output 4 Connect the purple fixture lead to the DIM V lead 5 Connect the gray fixture lead to the DIM V lead 6 Cap the yellow fixture lead if present Do NOT connect CLEANING MAINTENANCE CAUTION Be sure fixture temperature is cool enough to touch Do not clean or maintain while fixture is energized 1 Clean glass lens with non abrasive glass clea...