Wiring

Red pigtail is only used to switch remote or additional fixtures.

1.   Attach the Universal Mounting bar with the screws provided 

to the junction box. If you are attaching your STL360 kit to a 
surface mount weatherproof box, you must use with the metal 
mounting plate with gasket.

2.  

Easy Wiring Tip:

  Use the “S” shaped 

Hands Free Hanging Hook to hold 
the CU4 EZ Plate during wiring.

3.   Bring power leads and sensor 

kit leads through holes in gasket 
and plate into junction box.

4.   Strip 1/2" of insulation from all leads.
5.   Attach ground wire(s) to junction box 

grounding screw. Connect as shown in 
wiring diagram as shown in 

Fig. 2

.

6.   Twist on wire nuts. Secure with electrical tape.
7.   Align CU4 EZ Plate and metal surface plate with gasket 

(for 

use with surface mounted junction boxes)

 to ensure proper seal. 

Tighten CU4 EZ Plate center screw 

(make sure O-Ring gasket is on 

the screw)

 to attach CU4 EZ Plate to the box.

8.   Insert plastic Finishing Cap in the center of the CU4 EZ Plate for a 

weatherproof seal.

9.   Use silicone sealant around plate and all opening to ensure a 

weather proof seal. Seal all unused conduit entries on surface 
junction box.

10.  Screw in light bulbs. Turn on power. Conduct walk test to adjust 

sensor response 

(see page 6)

.

  

To install a STL360 Sensor with separately purchased 
floodlights, start at #1.

  

To install STL360 Pre-wired Floodlight Kits refer to 

Fig. 2

.

1.   Screw the threaded arms of each floodlight into the RAB CU4 EZ 

Plate. 

(See 

Fig. 1

.)

2.   Screw the threaded arm of the sensor into the bottom hole of 

the CU4 EZ Plate. Sensor should be below and as far away from 
the floodlights as possible.

3.   Attach the Universal Mounting bar with the screws provided to 

the junction box. If you are attaching your STL360 kit to a surface 
mount weatherproof box, you must use the metal mounting 
plate with gasket.

4.   Use the “S” shaped Hands Free Hanging Hook to hold the EZ 

Plate during wiring.

5.   Bring power leads and sensor kit leads through holes in gasket 

into junction box.

6.   Attach ground wire(s) to junction box grounding screw.
7.   Position CU4 EZ Plate and metal surface plate with gasket 

(required for mounting on surface junction boxes.) (See 

Fig. 1

.) 

8.   Strip 1/2” of insulation from 

all leads. Connect as shown 
in wiring diagram.

9.   Twist on wire nuts. Secure 

with electrical tape.

10.  Make sure all unused 

openings in CU4 EZ Plate are closed with plugs 

(provided)

.

11.  Use silicone sealant around plate and all openings to ensure a 

weather proof seal. Seal all unused conduit entries on surface 
junction box.

12.  Screw in light bulbs. Turn on power.
13.  Conduct walk test to adjust sensor response 

(see page 6)

.

Multiple Sensors

 

Multiple sensors may be wired together, but doing this will make 
problems difficult to troubleshoot. Single sensors that control their 
own lights will give a more accurate location of movement and 
trouble-free operation.

Multiple Fixtures

 

Multiple fixtures may be wired to a single sensor. To handle loads 
greater than 1000 watts, a qualified electrician should install a relay.

Black

Power In

White

Ground

Ground

White

Black

Red

Red Pigtail

Hood rests 

in notch on 

crossbar

Hands Free 

Hanging 

Hook

CU4 EZ Plate

Fig: 2

ASSEMBLY AND WIRING (cont’d)

Summary of Contents for STL360HB/L

Page 1: ...ERENCE RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes Proper grounding is required for safety THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WI...

Page 2: ...seconds then back on Will STL360 detect animals STL360 may detect large animals Having animals trigger the sensor can give property a lived in look However you can limit animal detection by turning d...

Page 3: ...should be mounted level from side to side and pointed at the area where you desire coverage If tilted part of the detection zone may be high in the air over people s heads Locate for Movement Across P...

Page 4: ...dlights start at 1 To install STL360 Pre wired Floodlight Kits refer to Fig 2 1 Screw the threaded arms of each floodlight into the RAB CU4 EZ Plate See Fig 1 2 Screw the threaded arm of the sensor in...

Page 5: ...look by simulating an occupant turning lights on at dusk and then off at bedtime To activate the EVENING TIMER flip the wall switch controlling the sensor three times slowly off on off on off on withi...

Page 6: ...utomatic Mode after completing the warm up period Daytime 24 HOUR Operation of Manual Override If you set Manual Override while set to 24 hour operation lights will come on and remain on continuously...

Page 7: ...triggering sensor Make sure the sensor is below and as far as possible away from lights Lights Turn On and Off Inappropriately 1 Make sure the sensor is installed on its own dedicated circuit free of...

Page 8: ...higher ambient light levels Alternatively move the lights or reflectors or mask the lens in the direction of the lights and or reflections 2 Check if R lamps non reflector A lamps or self ballasted P...

Page 9: ...ech Help Line Call our experts 888 722 1000 e mail Answered promptly sales rablighting com Free Lighting Layouts Answered online or by request 2022 RAB LIGHTING Inc Northvale New Jersey 07647 USA RAB...

Reviews: