INSTRUCTIONS
STL360H/L, STL360HB/L INSTALLATION
RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install
and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]
4
Wiring
Red pigtail is only used to switch remote or additional fixtures.
1. Attach the Universal Mounting bar with the screws provided
to the junction box. If you are attaching your STL360 kit to a
surface mount weatherproof box, you must use with the metal
mounting plate with gasket.
2.
Easy Wiring Tip:
Use the “S” shaped
Hands Free Hanging Hook to hold
the CU4 EZ Plate during wiring.
3. Bring power leads and sensor
kit leads through holes in gasket
and plate into junction box.
4. Strip 1/2" of insulation from all leads.
5. Attach ground wire(s) to junction box
grounding screw. Connect as shown in
wiring diagram as shown in
Fig. 2
.
6. Twist on wire nuts. Secure with electrical tape.
7. Align CU4 EZ Plate and metal surface plate with gasket
(for
use with surface mounted junction boxes)
to ensure proper seal.
Tighten CU4 EZ Plate center screw
(make sure O-Ring gasket is on
the screw)
to attach CU4 EZ Plate to the box.
8. Insert plastic Finishing Cap in the center of the CU4 EZ Plate for a
weatherproof seal.
9. Use silicone sealant around plate and all opening to ensure a
weather proof seal. Seal all unused conduit entries on surface
junction box.
10. Screw in light bulbs. Turn on power. Conduct walk test to adjust
sensor response
(see page 6)
.
■
To install a STL360 Sensor with separately purchased
floodlights, start at #1.
■
To install STL360 Pre-wired Floodlight Kits refer to
Fig. 2
.
1. Screw the threaded arms of each floodlight into the RAB CU4 EZ
Plate.
(See
Fig. 1
.)
2. Screw the threaded arm of the sensor into the bottom hole of
the CU4 EZ Plate. Sensor should be below and as far away from
the floodlights as possible.
3. Attach the Universal Mounting bar with the screws provided to
the junction box. If you are attaching your STL360 kit to a surface
mount weatherproof box, you must use the metal mounting
plate with gasket.
4. Use the “S” shaped Hands Free Hanging Hook to hold the EZ
Plate during wiring.
5. Bring power leads and sensor kit leads through holes in gasket
into junction box.
6. Attach ground wire(s) to junction box grounding screw.
7. Position CU4 EZ Plate and metal surface plate with gasket
(required for mounting on surface junction boxes.) (See
Fig. 1
.)
8. Strip 1/2” of insulation from
all leads. Connect as shown
in wiring diagram.
9. Twist on wire nuts. Secure
with electrical tape.
10. Make sure all unused
openings in CU4 EZ Plate are closed with plugs
(provided)
.
11. Use silicone sealant around plate and all openings to ensure a
weather proof seal. Seal all unused conduit entries on surface
junction box.
12. Screw in light bulbs. Turn on power.
13. Conduct walk test to adjust sensor response
(see page 6)
.
Multiple Sensors
Multiple sensors may be wired together, but doing this will make
problems difficult to troubleshoot. Single sensors that control their
own lights will give a more accurate location of movement and
trouble-free operation.
Multiple Fixtures
Multiple fixtures may be wired to a single sensor. To handle loads
greater than 1000 watts, a qualified electrician should install a relay.
Black
Power In
White
Ground
Ground
White
Black
Red
Red Pigtail
Hood rests
in notch on
crossbar
Hands Free
Hanging
Hook
CU4 EZ Plate
Fig: 2
ASSEMBLY AND WIRING (cont’d)