CLEANING & MAINTENANCE

CAUTION: Be sure fixture temperature is cool enough to touch.  

Do not clean or maintain while fixture is energized.

1.  Clean acrylic lens with non-abrasive cleaning solution.
2. 

Do not open the fixture to clean the LEDs. Do not touch 

the LEDs.

TROUBLESHOOTING

1. Check that the line voltage at the fixture is correct.              

    Refer to wiring directions.

2. Is the fixture grounded properly?

Note:

 These instructions do not cover all details or variations in equipment 

nor  do  they  provide  for  every  possible  situation  during  installation,  operation                                             
or maintenance.

Universal voltage driver permits operation at 120V through 277V, 
50 or 60 Hz. For 0-10V dimming, follow the wiring directions as 
shown in 

Fig. 12.

1. 

Connect the black fixture lead to the LINE supply lead.

2. 

Connect the white fixture lead to the COMMON supply lead.

3. 

Connect the GROUND wire from fixture to supply ground. 

4. 

Connect the purple fixture lead to the (V+) DIM lead.

5. 

Connect the pink fixture lead to the (V-) DIM lead.

6. 

 Cap the yellow fixture lead, if present. Do NOT connect.

0-10V DIMMABLE WIRING

PINK 

LIGHT

FIXTURE

Vaux 12V

YELLOW

GROUND

GROUND

( - ) DIM V

( + ) DIM V

COMMON

LINE

BLACK

WHITE

PURPLE