EZPAN   EDGELIT PANEL  2X2              

INSTALLATION INSTRUCTIONS

Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. 
Call the Marketing Department at 888-RAB-1000 or email: [email protected]

TM  

Access Plate

Conduit Knockouts

SAFETY INSTRUCTIONS

WARNING: Risk of fire or electric shock. Suitable for Damp locations. 
WARNING: Suitable for 9/16” or 15/16” Flat Tee Grid in both Insulated Ceilings and Non-Insulated Ceilings. Access above 

ceiling required. 
WARNING: Do not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or in water.
WARNING: Vapor barrier must be suitable for 90° C.
WARNING: Fixture to be independently supported to building structure.

IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding 

is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A 

PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
Make certain power is OFF before installing or maintaining fixture.

Fixture

Grid Clip (4)

Tee-Grid 

Bar

Access Plate Screw

Splice Box

 2 

Grid Clip 

Hole

Grid 

Clip

Power 

Feed

Fixture

Firmly bend Grid 

Clips up and out

RECESSED CEILING MOUNTING

The fixture is suitable only for INDOOR RECESSED CEILING 

application. Above ceiling access required.
To mount in an insulated or non-insulated ceiling - 9/16” or 

15/16” exposed Flat Tee Grid Ceiling follow the steps below. 
1.  Firmly bend the pre-installed Grid Clips (4) up and out 

as shown in Fig. 1. 

2.  Rotate and slide the Fixture as required to fit through 

the Tee-Grid Bar and place it as indicated by the 

directional arrow as shown in Fig. 2. Secure the Fixture 

to the  Tee-Grid Bar

3.  Support wires are required by Installation Codes. 

Support the Fixture to the building structure by 

Support Wires (supplied by others) through the Grid 

Clip Hole as shown in Fig. 3.

4.  Make sure that the orientation of the Splice Box and 

Access Plate faces an accessible tile to make electrical 

splices. 

5.  Loosen Access Plate Screw and remove the Access 

Plate. Knock out appropriate Conduit Knockouts 

on the Access Plate to route input conduit. Use 

appropriate conduit connectors as required by code   

(Fig. 4.).

6.  Connect wires as shown in wiring diagram. Push all 

wires back into the Splice Box. Use appropriate UL 

approved wire connectors as required by code to 

complete wiring. Terminal Block accepts input power 

wires of 16-18 AWG. If electrical supply wire is greater 

than 16 AWG the installer must connect using a              

16 AWG Pigtail (supplied). Be careful not to pinch wires. 

WARNING: To prevent wiring damage or abrasion, do 

not expose wiring to edges of sheet metal or other 

sharp objects. 

7.  Replace Access Plate and tighten Access Plate Screw.

Support Wire 

(supplied by 

others)

Fig. 2

Fig. 1

Fig. 3

Fig. 4