4
E
N
Daily
•
Use a dry cloth to clean the product
•
Visual inspection. Repair or replace any damaged or
worn-out parts
•
Ensure that all fasteners are in place and fitted correctly
•
Check all fittings and buckles for signs of worn out parts
•
Be aware of any MAX mark indications before adjust-
ment
Weekly
•
Wipe off any residue and dirt from the product using a
cloth with warm water and a mild detergent/soap and
dry before use
•
Disinfect the product. please check the disinfection section in this
User Guide for more information
Monthly
•
All nuts and bolt on this product must be checked and
tightened to avoid unnecessary failures
•
Oil the swing-away parts. We recommend you use a
professional lubricant system
Annually
•
Inspect the product for cracks or signs for worn-out
parts and carry out annual service. Never use a product
which appears to be substandard or faulty
Washing:
The cushion is removable and the cover can be washed at
max. 40° using a mild detergent in a washing machine. The
upholstery is incontinence proof and can be hand washed
in warm water. Let the foam cushions dry before inserting
them back into the cushion cover The condition of the up-
holstery should be checked at least every six months and
replaced if necessary. It is important to keep the frame clean
to maintain the validity of the chair.
Warewashing machine
This product can be washed at 60° using a mild detergent
for 15-20 minutes in a warewashing washing machine
designed for medical devices. Use the machine’s drying
function to dry the product. Remove all accessories and
cushions before washing the main product. Clean the ac-
cessories separately. Please allow the product to dry before
reuse.
Disinfection
The product without accesories and cushion can be disin-
fected with a 70% disinfectant solution. It is recommended to
wipe off any residue and dirt from the product, using a cloth
with warm water and a mild detergent/soap without chlorine
and let it dry before disinfection.
Service interval
A detailed inspection of the product must be made every 12
months (every 6 months for heavy users) and every time
the product is reissued for use. The inspection should be
carried out by a technically competent person who has been
trained in the use of the product.
The lifetime of this product in normal use is 5 years if all
maintenance and servicing is carried out in accordance with
the manufacturer’s instructions and demonstrably recorded.
Accessories and spare parts
The products from R82 can be supplied with a variety of
accessories which comply with the needs of the individual
user. Spare parts can be ordered on request. Find the spe-
cific accessories on our website or contact your local dealer
for further information.
TECHNICAL DATA
Seat:
ABS: Acrylonitrilbutadienstyren. Recyclable
Foam: Flameproof
Cover: Gemma
PRODUCER
R82 A/S
Parallelvej 3
8751 Gedved
DISTRIBUTOR
Please find your distributor on www.R82.org
Service Check List
Check and adjust the following functions as per their intend-
ed use. Repair or replace any damaged or worn-out parts.
Please check the:
•
Gas-spring for back recline and the handle for locking
the back in position.
•
Accessories can be inserted and locked in the fittings in
the top of the back, using the knob and handles mount-
ed in the fittings.
•
Inserts for fittings in the back and seat is in good condi
-
tion
•
Nuts and bolts on the product are tightened
•
Fittings and buckles for signs of worn out parts
•
Product for cracks or signs for worn-out parts
•
All labels on the product are intact
Presales information
•
Please go to support.r82.org
Service information
Maintenance of a medical device is wholly the responsibility
of the owner of that device. Failure to maintain a device in
accordance with the instructions may invalidate the device’s
warranty. Furthermore, failure to maintain a device may
compromise the clinical condition or safety of users and/or
their caregivers.