TABLE D - MEASURE TESTS CARD
Model VJ15000-TR
Volt Fil.
Current
Fil.
VA
IA
VG1
IG1
VG2
IG2
I° STEP input
3,9 VAC
1,665
VAC
107,0 mV
-
-
-
-
-
II° STEP input
6,250 VAC
1,775
VAC
171,0 mV 249 mV
141 mV
2,397
VDC
-
-
I° STEP Out Test
Point
2,254 VDC
2,639
VDC
2,450
VDC
-
-
-
-
-
II° STEP Out Test
Point
3,9 VDC
3,029
VDC
3,9 VDC 3,9 VDC
3 mV
3,9 VDC
-
-
I° STEP Strument
Measure
3,8 VAC
140 A
5000 VDC
-
-
-
-
-
II° STEP Strument
Measure
6,3 VAC
160 A
7500 VDC
3 A
71 VDC
1,0 A
-
-
I° STEP LCD
Measure
3,7 VAC
140 A
5000 VDC
-
-
-
-
-
II° STEP LCD
Measure
6,3 VAC
160,0 A 7500 VDC
3 A
71 VDC
1,0 A
-
-
I° STEP Fluke
Measure
3,9 VAC
140 A
5000 VDC
-
-
-
-
-
II° STEP Fluke
Measure
6,250 VAC
160 A
7500 VDC
3 A
71 VDC
1,0 A
-
-
On the measure card there are n°2 trimmer P18 corresponding to VG1 voltage presence and
P19 for VA voltage presence.
These two trimmers set the thresholds for the VG1 and IA voltage presence on the
equipment.
Once that is been verified the voltages presence, the relays are closed to enable the
protection box and leds D17 and D19 are light on to signal the controlled voltage presence.
In case that on the equipment is installed a triode tube, the checking of the VG1 is excluded
because this voltage is created automatically when the tube is in power and is created
inserting the jumper JP14 to have a short circuit so that the starting sequence is ok,
otherwise the equipment never go in high tension.