background image

 

 

iii 

Important Safeguards and Warnings 

1

Electrical safety 

 

All installation and operation here should conform to your local electrical safety codes.  

 

The power supply shall conform to the requirement in the SELV (Safety Extra Low Voltage) and 

must make sure that the limited power source is rated 12V DC or 24V AC. 

 

 

Please note: Do not connect two power supplying sources to the device at the same time; it 

may result in device damage! 

 

 

We assume no liability or responsibility for all the fires or electrical shock caused by improper 

handling or installation.  

 

We are not liable for any problems caused by unauthorized modification or attempted repair. 

 

2

Transportation Security 

 

Please ensure that the product does not endure heavy stresses, violent vibration or contact with 

water during transportation, storage and installation.  

 

Please use the original packing material (or the material of the same quality) if you need to return it 

to vendor.  

 

3

Installation 

 

Do not apply power to the product before completing installation.  

 

Do not put object(s) on the product. 

 

Please install a proper power cut-off device during the installation connection. 

 

4

Qualified engineers needed 

 

All the examination and repair work should be done by the qualified service engineers.  We are not 

liable for any problems caused by unauthorised modifications or attempted repair. 

 

5.  Environment

 

 

This product should be installed in a cool, dry place away from direct sunlight, inflammable, 

explosive substances and etc. 

 

Please keep it away from environments that contain electromagnetic radiation or objects that 

produce it. 

 

Please keep sound ventilation around the device at all times.  

 

Do not allow the water and other liquid to penetrate into the device if casing has been 

compromised. This series product complies with the IP66 standard specified in the Degrees of 

Protection Provided by Enclosure. 

 

Ensure lightning surge protection is in place to make sure you fully protect camera circuitry from 

electrical overload. 

Summary of Contents for APOIP-EYE1.3

Page 1: ...APOIP EYE1 3 APOIP EYE2 1 3 2 MEGA PIXEL EYEBALL DOME IP CAMERAS User s Manual...

Page 2: ...i...

Page 3: ...designed to be a reference tool for the installation and operation of your system Here you can find information about the corresponding IP camera s features and functions as well as a detailed install...

Page 4: ...ame quality if you need to return it to vendor 3 Installation Do not apply power to the product before completing installation Do not put object s on the product Please install a proper power cut off...

Page 5: ...ce You can use the dry cloth with some alcohol or mild detergent to clear if necessary When the camera is not in use please put the dustproof cap to protect the CCD CMOS component Do not use volatile...

Page 6: ...ory Default Setup 4 2 Structure 9 2 1 Components 9 2 2 Framework and Dimension 10 3 Device Installation 11 3 1 Installation Steps 11 3 2 Restore Factory Default Setup Introduction 13 4 Quick Configura...

Page 7: ...at the same time via the inbuilt microphone If you want to communicate with a person s in view of the camera it also supports dual way bidirectional talk The built in protection enclosure and waterpro...

Page 8: ...66 protection testing It can withstand a variety of weather conditions and outdoor environments 1 3 Specifications 1 3 1 Performance Please refer to the following sheet for network camera performance...

Page 9: ...The 6th level has the highest sensitivity Activation event video storage image snapshot log email function and etc Record and Backup Record Priority Manual External alarm Video detect Schedule Storage...

Page 10: ...0 50 Scene Mode Auto Day night Mode Auto BLC Off Mirror Off Flip Off Video Video bit stream Main Stream Bit stream type General Encode mode H 264 Resolution 720P 1280x96 1080P 1920x1080 Frame Rate FP...

Page 11: ...Snapshot Path C PictureDownload Record Path C RecordDownload Network TCP IP Host Name IPC Ethernet Card Wire Default Mode Static Mac Address Device MAC address when it is shipped out of the factory I...

Page 12: ...s IP Filter Trusted sites Disable SMTP Email SMTP Server none Port 25 Anonymity Disable User Name anonymity Password Sender none Authenticatio n Encryption mode N A Title Subject IPC Message Attachmen...

Page 13: ...e Snapshot Disable Video Masking Enable Disable Record Channel Enable Record Delay 10 seconds Send Email Disable Snapshot Disable Storage Storage FTP Enable FTP Disable Server IP N A Port 21 Username...

Page 14: ...YE1 3 APOIP EYE2 DST Disable DST Type Week Start Time 00 00 00 of the first Sunday of the month End Time 00 00 00 of the second Monday of the month NTP Disable NTP Server clock isc org Port 37 Update...

Page 15: ...on cable information see Figure 2 1 Figure 2 1 Please refer to the following sheet for detailed information No Port Name Connector Note 4 LAN Network port Ethernet To connect to standard Ethernet 5 DC...

Page 16: ...ht Qvis All documentation rights reserved 10 2 2 Framework and Dimension Please refer to the following two figures for dimension information The unit is mm See Figure 2 2 and Figure 2 3 Figure 2 2 Fig...

Page 17: ...bolts in the holes Secure these three bolts firmly Please draw the cable out from the cable exit when you install the device Step 3 Adjust the device installation pedestal to the proper position and...

Page 18: ...n See Figure 3 2 Figure 3 2 Note This series product supports two cable exits One is from the bottom and the other is from the side Please refer to the following figure for cable exit from the side in...

Page 19: ...he dome body from the dome cover Step2 Take the dome body out and then turn the top cover hard to remove Step3 Slightly press the RESET button to complete the reset function see Figure 3 5 Step4 Turn...

Page 20: ...ault gateway MAC address etc Figure 4 1 Search interface Select one IP address and then right click mouse you will see an interface like the one shown in Figure 4 2 Note You can set the IP address sub...

Page 21: ...to the device web interface you can go to the configuration tool s main interface to set In the configuration tool s search interface Figure 4 1 please select a device IP address and then double click...

Page 22: ...vice If you are using device background upgrade port 3800 to login other setups are all invalid Figure 4 4 Login prompt After you logged in the configuration tool main interface is shown as below See...

Page 23: ...twork camera default IP address is 192 168 1 108 Subnet mask is 255 255 255 0 Gateway is 192 168 1 1 Use order ping network camera address to check connection is OK or not 5 2 Login and Logout 1 Open...

Page 24: ...or not after you have logged in for one minute Please click OK button the system can automatically install the control When system is upgrading it can overwrite the previous Web as well If you can t d...

Page 25: ...Copyright Qvis All documentation rights reserved 19 After you logged in you can see the main window See Figure 5 4 Figure 5 4 Web monitoring window...

Page 26: ...ked The display card version needs to be DX8 1 or higher Network connection error occurred Invalid network setup Invalid user name or password I cannot play the download file There is no player There...

Page 27: ...hts reserved 21 For more information about our IP Cameras and other available cameras NVRs accessories please visit our website www adata co uk Alternatively scan this QR code with your smart phone to...

Reviews: