QM1014 LO Synthesizer Distribution Unit
User Manual
1. Input/Output Specifications
Table 1.1:
Input/Output Specifications
Parameter
Min
Typ
Max
Unit
External Reference Input*
Frequency
10
MHz
Power Level
4
10
16
dBm
10 MHz Reference Output
Frequency
10
MHz
Power Level
5
dBm
Type: Sine Wave
External LO1 Output
Frequency
𝑓
𝑇 𝑢𝑛𝑒
< 1.05 GHz
𝑓
𝑇 𝑢𝑛𝑒
+ 9.5
GHz
1.05 GHz
≤
𝑓
𝑇 𝑢𝑛𝑒
< 1.45 GHz
𝑓
𝑇 𝑢𝑛𝑒
+ 10.0
GHz
1.45 GHz
≤
𝑓
𝑇 𝑢𝑛𝑒
< 2.85 GHz
𝑓
𝑇 𝑢𝑛𝑒
+ 9.5
GHz
2.85 GHz
≤
𝑓
𝑇 𝑢𝑛𝑒
< 3.05 GHz
𝑓
𝑇 𝑢𝑛𝑒
+ 10.0
GHz
3.05 GHz
≤
𝑓
𝑇 𝑢𝑛𝑒
< 4.55 GHz
𝑓
𝑇 𝑢𝑛𝑒
+ 9.5
GHz
4.55 GHz
≤
𝑓
𝑇 𝑢𝑛𝑒
< 4.85 GHz
𝑓
𝑇 𝑢𝑛𝑒
+ 10.0
GHz
4.85 GHz
≤
𝑓
𝑇 𝑢𝑛𝑒
< 5.85 GHz
𝑓
𝑇 𝑢𝑛𝑒
+ 9.5
GHz
𝑓
𝑇 𝑢𝑛𝑒
≥
5.85 GHz
𝑓
𝑇 𝑢𝑛𝑒
+ 10.0
GHz
Power Level
-5
dBm
External LO2 Output
Frequency
𝑓
𝑇 𝑢𝑛𝑒
< 2.85 GHz
12.0
GHz
2.85 GHz
≤
𝑓
𝑇 𝑢𝑛𝑒
< 3.05 GHz
12.5
GHz
3.05 GHz
≤
𝑓
𝑇 𝑢𝑛𝑒
< 4.55 GHz
12.0
GHz
4.55 GHz
≤
𝑓
𝑇 𝑢𝑛𝑒
< 4.85 GHz
12.5
GHz
4.85 GHz
≤
𝑓
𝑇 𝑢𝑛𝑒
< 5.85 GHz
12.0
GHz
𝑓
𝑇 𝑢𝑛𝑒
≥
5.85 GHz
12.5
GHz
Power Level
0
dBm
* NOTE: The external reference must be blocked or held at 0V DC. DC bias not allowed and not blocked
internally.
Quonset Microwave
Revision 1.2.1
3