Section VI – Operating instructions
80 Quincy Vacuum Pump-QSV Series
Operating instructions
6.1 Initial start-up
CAUTION!
The operator must apply all relevant Safety precautions. Also consult section Problem solving
.
• Remove the service canopy panel(s) in order to get access to the internal components.
• Remove the red transport spacers and the related bolts under element (1), coupling housing (2) and oil
separator tank (3).
• Check that the electrical connections correspond to the local codes and that all wires are clamped tight
to their terminals.
• The installation must be earthed and protected against short circuits by fuses of the inert type in all
phases. It is advised to install an isolating switch near the vacuum pump.
• Check the process lines for the correct size to prevent high pressure drop and for cleanliness to protect
the vacuum pump. Also check for leaks.