Instruction book
2012 2039 28
68
■■ Re-grease motor bearings
Every 8000 hours
■■ Oil Separator kit & Scavenge Line Kit
■■ Unloader Kit
■■ Oil Stop and Check Valves Kits
■■ Minimum Pressure Valve Kit
■■ Thermostatic Valve Kit
■■ Change the Fluid*
■Operations that may be carried out by the user
■■ Operations that require skilled personnel
* The compressor must be maintained with QuinSyn
‐
Plus (8,000-hour maximum), QuinSyn
‐
XP (12,000 hour
maximum) or QuinSyn
‐
F food grade (6,000 hour maximum). Maximum fluid change intervals are noted
per fluid. Actual fluid change interval is to be determined by fluid sampling report, not to exceed maximum
fluid change interval. Fluid samples must be taken every 2,000 hours or as directed by the analysis report.
For light usage units, a fluid sample must be taken a minimum, of every six (6) months, beginning at
start
‐
up.
Always consult your supplier if a service timer setting has to be changed.
For the change interval of fluid and oil filter in extreme conditions, consult your
Customer Centre.
Any leakage should be attended to immediately. Damaged hoses or flexible joints
must be replaced.
6.2
Storage after installation
Service kits
Run the compressor regularly, e.g. twice a week, until warm. Load and unload the compressor a few times.
If the compressor is going to be stored without running from time to time, protective
measures must be taken. Consult your supplier.