QHPR Installation & Operating Instructions
Maintenance
QHPR dryers require little maintenance
for satisfactory operation. Good dryer
performance can be expected if the
following routine maintenance steps are
taken.
Daily Maintenance
Check the separator for condensate
discharge. If no discharge is evident,
depressurize, dismantle and clean
separator housing with mild soap and
water. Discard the automatic float drain
and replace.
Monthly Maintenance
Inspect the condenser coils. Remove
accumulated dust and dirt with a soft
brush or with air from an OSHA approved
compressed air nozzle that limits the
discharge pressure to 30 psig.
General
For continued good performance of your
refrigerated dryer, all refrigeration system
maintenance should be performed by a
competent refrigeration mechanic.
notiCe!
Before corrective maintenance is done
during the warranty period, call your
local distributor and proceed according
to instructions. Refer to the warranty
for limits of your coverage.
Maintenance Parts List
I
tem
QHPR-5/10
QHPR-15
O
n
/O
ff
S
wItcH
3245021
3245021
f
lOat
D
RaIn
K
It
3090900
3090900
6
Quincy Compressor-QHPR Series Dryers