quiko QK-CE220RLE User Manual Download Page 1

ELECTRONIC CONTROL UNIT  
QK-CE220RLE 

 

Single-phase  electronic  control  unit  for  the  automation  of 
sliding gates with incorporated radio receiver. 

 

TECHNICAL DATA: 

 

- Power supply                      : 230 V ac  50-60Hz 1100W max.

 

- Flashing beacon output         : 230 V ac 500 W max.

 

- Motor output 

                     : 230 V ac 500 W max.

 

- Auxiliary power output 

       : 24 V a/c 3 W max.

 

- Stop limit and low voltage commands  : 24 V cc

 

- Working temperature 

       : -10 

÷

 55 °C

 

- Radio receiver                       : see model

 

- Op. transmitters                     : 12-18 Bit or Rolling Code

 

- Max stored TX codes 

       : 215 (CODE + CODE PED)

 

- Box dimensions  

       : 110x121x47 mm.

 

- Container 

                     : ABS V-0  (IP54).

 

 

TERMINAL BOARD CONNECTIONS: 

 

CN1: 
1  : 230 V a/c line input (Phase). 
2  : 230 V a/c line input (Neutral). 
3  : 230 V a/c flashing line input (Neutral). 
4  : 230 V a/c flashing line input (Phase). 
5  : Opening motor output. 
6  : Common motor output. 
7  : Closing motor output. 

 

CN2: 
1  : Service power supply output 24 V a/c 3 W. 
2  : Service power supply output 24 V a/c 3 W. 
3  : Open-close command button input (NA). 
4  : Common GND input. 
5  : Safety device input (NC). 
6  : Opening stop limit input (NC). 
7  : Common GND input. 
8  : Closing stop limit input (NC). 
9  : Earth antenna input. 
10: Antenna hot pole input. 

 
FUNCTIONAL DATA:

 

 

Step-by-Step Operation: 

Using  both  the  radio  control  (CODE  LED  illuminated)  and  the 
low  voltage  push-button  station  (PUL)  to  control  the  gate, the 
following operation is obtained: 
the  first  impulse  opens  the  gate  until  the  motor  timer  reaches 
zero  or  until  the  opening  stop  limit  is  reached,  the  second 
impulse  closes  the  shutter;  if  an  impulse  arrives  before  the 
opening  stop  limit  is  reached,  the  control  unit 

stops 

motion 

during  both  opening  and  closing.  A  futher  command  restarts 
motion in the opposite direction.

 

 

Automatic closing: 

The  control  unit  can  close  the  gate  automatically  without 
sending additional commands. 
The selection of this operation mode is described in the Pause 
Time programming mode. 

 
Pedestrian Passage: 

If selected (PED CODE LED illuminated), using the pedestrian 
radio  control  to  control  the  gate,  the  following  operation  is 
obtained:  the first press is a command for the gate to open for 
10  seconds,  then  the  control  unit  pauses  for  10  seconds  and 
the gate closes again.

 

 

Safety device: 

The  control  unit  enables  power  supply  and  connection  for 
photoelectric cells and pneumatic buffers (NC). 

 

No  action  is  taken  into  account  during  the  opening  stage  and 
causes inverted motor action during the closing stage. 
If not used, this input must be bridged. 
 

Initial pick-up and Motor Power Adjustment: 

The  electronic  control  unit  is  equipped  with  initial  pick-up  and 
motor  power  adjustment  functions  that  are  fully  managed  by 
the microprocessor.  

 

The initial pick-up function is used to help the motor in its initial 
activation  stage,  powering  it  at  the  maximum  level  for  2 
seconds,  even  if  the  motor  power  adjustment  function  is 
enabled. 
The  motor  power  adjustment  function  is  used  to  ensure  the 
correct  motion  of  the  gate,  blocking  it  in  case  of  obstruction 
without causing harm to individuals or their property.  
 

Deceleration:

 

The  motor  deceleration  function  is  used  to  avoid  the  gates 
moving  at  high  speed  towards  the  end  of  the  opening  and 
closing stages.  

 

Deceleration can be programmed for the desired points (before 
the  gates  are  totally  open  or  closed)  during  Motor  Timer 
programming. 
 

Flashing Beacon Operation:

 

The control unit is equipped with output for a 230 V a/c flashing 
beacon.  The flashing beacon is only activated when the motor 
is running.  

 

 
Operation with TIMER: 

The control unit may be connected to a timer instead of using 
the open-close command button (PUL). 

 

Example:  at  8:00  a.m.  the  timer  closes  the  contact  and  the 
control  unit  opens  the  gate;  at  6:00  p.m.  the  timer  opens  the 
contact and the control unit closes the gate. Between 8:00 a.m. 
and 6:00 p.m. at the end of the opening phase, the control unit 
disables the flashing beacon, the automatic closing stage and 
the radio controls.

 

 
PROGRAMMING:

 

 

SEL key:

 selects the type of function to be stored; selection is 

indicated by a flashing LED.

 

By  pressing  the  key  repeatedly,  you  can  select  the  desired 
function.    The  selection  remains  active  for  10  seconds 
(indicated  by  the  flashing  LED);  after  10  seconds,  the  control 
unit returns to its original status.

 

SET key:

 programmes the information according to the type of 

function selected previously using the SEL key.

 

IMPORTANT:

  The  function  of  the  SET  key  can  be  replaced 

with  the  radio  control,  if  programmed  previously  (CODE  LED 
on).

 

 

MAIN MENU 

The control unit is supplied by the manufacturer with the option 
of selecting a number of principal functions. 
 

---------------------- MAIN MENU -----------------

 

LED Reference           LED Off                               LED On 

1) CODE                        No code                          Code inserted 
2) CODE PED.                No code                          Code inserted 
3) INB.CMD.AP              Disabled                              Enabled 
4) LAMP/CORT.             Flashing                         Courtesy light 
5) T. MOT.           Programmed time 30 sec.        Programmed time 
6) T. PAUSA.          No automatic closure           Automatic closure 

 
1) CODE: 

 (Radio control code)

 

The  control  unit  can  store  up  to  215  radio  controls  with 
different fixed or rolling codes. 

 
 
 

GB 

Summary of Contents for QK-CE220RLE

Page 1: ...age If not used this input must be bridged Initial pick up and Motor Power Adjustment The electronic control unit is equipped with initial pick up and motor power adjustment functions that are fully managed by the microprocessor The initial pick up function is used to help the motor in its initial activation stage powering it at the maximum level for 2 seconds even if the motor power adjustment fu...

Page 2: ...e proceed as follows when the gate is closed use the SEL key to navigate to T MOT when the corresponding LED is flashing then press the SET key briefly and the Motor will begin its opening cycle when the initial point of deceleration is reached press the SET key again and the motor will decelerate until the desired position is reached Press the SET key to complete the opening cycle The T MOT LED w...

Page 3: ...imultaneous flashing beacon ON OFF F T PAUSA Simultaneous flashing beacon ON OFF A CODE Inversion Time Selection 1 s 0 5 s The control unit is supplied by the manufacturer with the time taken to invert the rotation movement of the motor set at about 1 second to increase the inversion speed to about 0 5 second proceed as follows check that extended menu 2 is enabled T MOT and T PAUSA LEDs start fla...

Page 4: ...n section 5 2 7 of EN 12453 Power supply leads and connection cables must be secured through the use of cable clamps which are supplied with the product The motor reducer used to move the shutter must comply with section 5 2 7 of EN 12453 If present the keypad for manual control must be mounted in such a way that the user is not placed in a dangerous situation in compliance with point 5 2 8 of EN ...

Page 5: ...QUIKO ITALY SAS hereby declares that the below products Electronic Control Unit QK CE220RLE comply with the requirements of Directives R TTE 99 5 EC EMC 2004 108 EC LVD 2006 95 EC ...

Reviews: