- 2 -
5. PRELIMINARY OPERATIONS
- Before sending a command to the automation, make sure to have selected correctly the type of bollard as follows:
Bollard selection
- Hold down buttons F and + for 2 seconds to select the connected bollard.
- Select the type of bollard using the b/-.
BOLLARD TABLE
QK-CT273600L QK-CT219500
QK-CT273800L/K4
QK-CT219700
QK-CT219500LFX QK-CT115500
QK-CT219700LFX QK-CT193700L
- Select network frequency through
parameter.
6. INPUT AND OUTPUT FUNCTIONALITY AND CONNECTIONS
. (see 3rd level programming).
-
(For
QK-CT273600L/ 800L/ K4
only)
S
elect the
closing limit switch type (NO or NC) with parameter PP (paragraph 7.4)
.
-
Check the connection method for simultaneous operation if controlling multiple devices simultaneously
(see
paragraph 9).
LINE
230V
230V 50/60Hz power supply with mov internal protection and 8A T fuse (5x20).
Connect the phase and neutral as shown on the screen printing. Use a cable type H07RN-F 2x1.5+E min.
Connect the yellow/green wire of the power supply mains to the earth terminal of the appliance.
OUT24
Output 24Vac, 1A MAX
LED (Cover lights)
Self-powered output. 24Vac, 100mA max
BZ (Cover buzzer)
Self-powered output. 24Vac, 100mA max
AUX
Programmable volt-free relay output, max. 500mA, 24Vac/dc. Use parameter
6.3
OUTPUTS/ACCESSORIES TERMINAL BLOCK
6.2
POWER TERMINAL BLOCK
L N E
24
V
ac
LED
24 Vac
BZ
BZ
AUX
AUX
MOTA
COM
MOTB
CAP
EV
CAP
EV
SL
GR
RD
M
MOTA/
OPEN
MOTB/C
LOSE
Motor capacitor
Electrovalve (230Vdc)
only
QK-CT273600
L
/ 800L /K4
Flashing light (230V)
CAP
CAP
EV
EV
SL (Flashing light)
SLCOM
GR (green light)
RD (red light)
COM
6.1
POWER TERMINAL BLOCK
Summary of Contents for QK-CE220CTN
Page 1: ...QK CE220CTN 1 3 V05 2014 ...