quiko QK-CE220CTN Installation And Operation Manual Download Page 2

Contents

Page

1. INTRODUCTION

1

2. MAIN CHARACTERISTICS

1

3. TECHNICAL SPECIFICATIONS

1

4. INSTALLATION SAFETY

1

5. PRELIMINARY OPERATIONS

2

6. INPUT AND OUTPUT FUNCTIONALITY AND CONNECTIONS

2

6.1 J2 POWER TERMINAL BLOCK 

2

6.2 J5 POWER TERMINAL BLOCK 

2

6.3 J7 OUTPUTS/ACCESSORIES TERMINAL BLOCK 

2

6.4 J9 INPUTS/OUTPUT TERMINAL BLOCK 

3

6.5 J10 ELECTRIC BRAKE TERMINAL BOARD/ANTENNA 

3

7. PROGRAMMING

4

7.1 BASIC FUNCTIONS 

4

7.2 1ST LEVEL PROGRAMMING 

5

7.3 2ND LEVEL PROGRAMMING 

6

7.4 3RD LEVEL PROGRAMMING 

7

8. 

9

9

9

10

10

11

12

   CONNECTIONS FOR SIMULTANEOUS OPERATION 

13

9. TROUBLESHOOTING GUIDE

10. ATTENTION

11. EXAMPLES OF CONTROLLING ENTRANCES

11.1 INSTALLATION A CONTROLLED ENTRANCE OR EXIT 

11.2 INSTALLATION B AUTOMATIC ENTRY OR EXIT 

11.3 INSTALLATION C CONTROLLED ENTRY AND EXIT 

11.4 INSTALLATION D CONTROLLED ENTRY AND AUTOMATIC EXIT 

Summary of Contents for QK-CE220CTN

Page 1: ...QK CE220CTN 1 3 V05 2014 ...

Page 2: ...ERMINAL BLOCK 3 6 5 J10 ELECTRIC BRAKE TERMINAL BOARD ANTENNA 3 7 PROGRAMMING 4 7 1 BASIC FUNCTIONS 4 7 2 1ST LEVEL PROGRAMMING 5 7 3 2ND LEVEL PROGRAMMING 6 7 4 3RD LEVEL PROGRAMMING 7 8 9 9 9 10 10 11 12 CONNECTIONS FOR SIMULTANEOUS OPERATION 13 9 TROUBLESHOOTING GUIDE 10 ATTENTION 11 EXAMPLES OF CONTROLLING ENTRANCES 11 1 INSTALLATION A CONTROLLED ENTRANCE OR EXIT 11 2 INSTALLATION B AUTOMATIC ...

Page 3: ...voltage fuse 5x20 5 0mA T F Programming push buttons LED FCA FCC STOP CLOSE OPEN PDM START FOTO Microprocessor logic LEDs displaying input status 2 digit display TERMON 4 INSTALLATION SAFETY In order to reach the level of safety required by current regulations read the following prescriptions carefully 1 Make all the connections in the terminal block after carefully reading the instructions given ...

Page 4: ...controlling multiple devices simultaneously see paragraph 9 LINE 230V 230V 50 60Hz power supply with mov internal protection and 8A T fuse 5x20 Connect the phase and neutral as shown on the screen printing Use a cable type H07RN F 2x1 5 E min Connect the yellow green wire of the power supply mains to the earth terminal of the appliance OUT24 Output 24Vac 1A MAX LED Cover lights Self powered output...

Page 5: ...automation performs the opening manoeuvre and will close automatically only when the input is freed Connect clocks daily timers or weekly timers here if wanted CLOSE N O input for closing It allows the automation to be closed only if the safety devices have not triggered Operating mode programmable with parameter 6 4 INPUTS OUTPUT TERMINAL BLOCK START COM PDM COM OPEN COM CLOSE COM 6 5 J10 ELECTRI...

Page 6: ... menu selecting the ST function with key F PLEASE NOTE If there is a black out when programming all changes will be lost F F F 2nd level 1 2 arm closed F F F F F F F F F F F F F x 2 x 2 x 5 x 3 x 4 1st level programming Selects each single 1st level function see table par 6 2 Selects each single 2nd level function see table par 6 3 Selects each single 3rd level function see table par 6 4 Changes t...

Page 7: ...t a d e l b a t t e S n o i t c n u F r e t e m a r a P Selects the functioning logic see notes after the table Hold to run Semi automatic Automatic see notes after the table Standard close input Close when released input The close command acts as a release closing and safety function Photocells During closure it reopens and waits for the photoelectric cell free commands When closing it reopens re...

Page 8: ...t for the signal to be released The close command acts as a release closing and safety function When closing the close command engaging stops the automation When disengaged the bollard resumes closing Default To reset the default parameters set parameter on 1 and exit the menu A B C and D set the corresponding default and quit the menu See chapter 12 for details on installation type Automation sta...

Page 9: ...meters Programming maintenance cycles in thousands and millions Thanks to the combination of the two parameters the countdown can be set after which a request for maintenance is signalled Thousands can be set with the parameter millions with the parameter Example to set 275 000 maintenance manoeu vres set on 0 2 and on 75 The value displayed in the parameters updates along with the manoeuvres 11 A...

Page 10: ...ailable for QK CT273600L 800L LIGHT CABLES Connect the YELLOW cables of the LED lamps in parallel FCA CABLES Connect the GREEN cables of the opening end of travel devices in series FCC CABLES For QK CT273600L 800L bollards supplied before 01 01 2013 BURGLAR CABLES Connect the ORANGE cables of the burglar device contact in series if available HEATING ELEMENT CABLES Connect the RED cables of the hea...

Page 11: ...e vehicle is on loop S1 the device will move down only after a recognition command If the device is moving back up and you want to lower it again the vehicle must be on loop S1 and then you must activate the recognition command When the vehicle is no longer on loop S2 the device will move back up Loops S1 and S2 also have a safety function in that they will not let the device move all the time the...

Page 12: ...ove back up Loops S1 and S2 also have a safety function in that they will not let the device move all the time the vehicle is on top Connect the N O contact of the coil receiver S1 to the OPEN input Connect the N O contact of the S2 loop receiver to input CLOSE The dimensional values of the loops are only approximate We suggest installing the QK LDT metal mass detector 11 2 INSTALLATION B AUTOMATI...

Page 13: ...XIT DIMENSIONS Connect the N O contact of the coil S1 and S2 receiver to input PDM The dimensional values of the loops are only approximate We suggest installing the QK LDT metal mass detector When the vehicle is on loop S2 the device will move down only after a recognition command If the device is moving back up and you want to lower it again the ve hicle must be on loop S1 and then you must acti...

Page 14: ... have a safety function in that they will not let the device move all the time the vehicle is on top ENTRY When the vehicle is on loop S1 the device will move down only after a recognition command If the device is moving back up and you want to lower it again the vehicle must be on loop S1 and then you must activate the recognition command The vehicle approaches the reserved area Connect the conta...

Page 15: ...ione Low voltage t Rispetta le seguenti parti clausole di norme tecniche armonizzate Respects the following parts clauses of harmonized technical standards EN 61000 6 1 EN 61000 6 2 EN 61000 6 3 EN 61000 6 4 EN 55014 1 EN 55014 2 t E conforme alle seguenti parti clausole di norme armonizzate Is in conformity with the following parts clauses of harmonized standards EN 60335 1 EN 60335 2 103 La QUIK...

Page 16: ...QUIKO ITALY Via Seccalegno 19 36040 Sossano VI Italy Tel 39 0444 785513 Fax 39 0444 782371 info quiko biz www quikoitaly com ...