FINAL TESTING
Once all connections have been done and the gate is closed, check that LEDs status is as follows:
LED STATUS TABLE
LD0
ON
LD1
OFF
LD2
OFF
LD3
OFF
LD4
ON
LD5
ON
LD6
ON
LD7
OFF
LD8
OFF
LD9
OFF
TROUBLESHOOTING
Problem
Solution
F1 or F2A fuses are fired or not properly inserted. Please check
230Vac (connectors 23 and 24) aren't connected. Please check.
Check that leds behaviour is as per the LED STATUS TABLE. Otherwise check connections
Check that on every START command the led LD2 switches ON. Otherwise memorise again the
remote button on the radio receiver or check key selector connections
Check that POWER TRIMMER is settled at least at the 2/3 of regulation
Reverse M1 motor cables to reverse the sense of rotation of the motor
Check M1 motor connections
If a electrical lock is installed, check that it is released properly once the gate is opening
Check that the 12Vdc common isn' t connected with the 24Vac
Take the antenna cables off and try again.
Change the battery of the remote and try again.
The LD0 led isn't switched ON so the control board isn't
supplied with electricity
A START command doesn't let the automation start
A START command let the flashing light start but doesn't
let the automation start
The remote cannot be memorised on the receiver