quiko QK-CE220BATRLE User Manual Download Page 4

4

EXTERNAL
PHOTOCELLS

CAPACITOR

FLASHING LIGHT 230Vac

KEY SELECTOR

OPEN/CLOSE SWITCH

COMMON

STOP
SWITCH

M1

MOTOR

COMMON

OPEN

CLOSE

230V 50/60Hz

CAPACITOR

MOTOR

M2

CLOSE

COMMON

OPEN

INTERNAL
PHOTOCELLS

COMMON

NOT USED

NOT USED

LAYOUT AND CONNECTIONS

JP1 Jumper for SETUP 

DIP SWITCHES for SETUP 

RADIO PROG. 
button for 
transmitters 
programming 

POWER TRIMMER 
for Power / force 
setting 

BREAK TRIMMER for 
Break/pause time setting

LD0 Mains 

supply 

led 

LD1 Radioreceiver 

status 

led 

LD2 Start 

signal 

led 

LD3 

Pedestrian start signal led 

LD4 

Internal photocell led 

LD5 External 

photocell 

led 

LD6 Stop 

signal 

led 

LD7 Not 

used 

LD8 Not 

used 

LD9 

Control board status led (it flashes when the 
automation is moving)  

Connector N°

Description

Type

Bypass if not 
used?

1-2

Antenna (1 signal, 2 screen)

-

-

3-5

Open/close switch and key selector

N.O.

NO

4-5

Pedestrian open/close switch

N.O.

NO

6-9

Internal Photocells. If excited this contact causes: DURING OPENING --> immediate stop of the gate 
and resume opening upon removal of the obstacle. DURING CLOSING --> immediate stop of the gate 
and resume opening. DURING PAUSE --> rejecting of start signals and 

recharge of pause time.

N.C.

YES

7-9

External Photocells. If excited this contact causes: DURING OPENING --> No effects. DURING 
CLOSING --> immediate stop of the gate and resume opening. DURING PAUSE --> recharge of pause 
time

N.C.

YES

8-9

Stop switch

N.C.

YES

12-14

Photocells and accessories output 24Vac 500mA

-

-

13-14

Electrical lock output 12Vac 15W

-

-

15-16-17

Motor 1 output (FIRST MOTOR TO OPEN) 230Vac single phase, connector 16 = common, connectors 
15-17 motor feeding and capacitor

-

-

18-19-20

Motor 2 output 230Vac single phase, connector 19 = common, connectors 18-20 motor feeding and 
capacitor

-

-

21-23

Flashing lamp output 230Vac 

-

-

-

23-24

Control board power supply 230Vac 50/60Hz

-

-

Summary of Contents for QK-CE220BATRLE

Page 1: ...E N G L I S H 433 92 MHz 230V PLUG PLAY 433 92 MHz 230V PLUG PLAY CONTROL BOARD FOR 1 2 230V ac SINGLE PHASE MOTORS user manu a l QK CE220BATRLE V03 2011 ...

Page 2: ...S INTRODUCTION MAIN FEATURES OF THE CONTROL BOARD TECHNICAL DATA INSTALLATION LAYOUT AND CONNECTIONS OTHER SETTINGS RADIORECEIVER SETUP SETUP FINAL TESTING TROUBLESHOOTING DECLARATION OF COMPLIANCE QUIKO GUARANTEE GENERAL CONDITIONS ...

Page 3: ...ne construction and is therefore included in the application of European directive 2006 42 EC Machinery Directive The above mentioned directive includes following prescriptions only trained and qualified personnel should install the equipment the installer must first make a risk analysis of the machine the equipment must be installed in compliance with the regulations in force after installation t...

Page 4: ...n close switch and key selector N O NO 4 5 Pedestrian open close switch N O NO 6 9 Internal Photocells If excited this contact causes DURING OPENING immediate stop of the gate and resume opening upon removal of the obstacle DURING CLOSING immediate stop of the gate and resume opening DURING PAUSE rejecting of start signals and recharge of pause time N C YES 7 9 External Photocells If excited this ...

Page 5: ...ETUP it is necessary to have a remote control which is already memorized in the receiver Enter the ray of action of the receiver with a remote control already memorized and maintain pressed two buttons of the same until the lighting of the flashing lamp Press the desired button of the new remote to be memorized The flashing lamp flashes to confirm the memorization of the new remote ...

Page 6: ...6 DIP3 to OFF pre flashing enabled DIP3 to ON pre flashing disabled ...

Page 7: ...the remote button on the radio receiver or check key selector connections Check that POWER TRIMMER is settled at least at the 2 3 of regulation Reverse M1 motor cables to reverse the sense of rotation of the motor Check M1 motor connections If a electrical lock is installed check that it is released properly once the gate is opening Check that the 12Vdc common isn t connected with the 24Vac Take t...

Page 8: ...rd QK CE220BATRLE complies with the main safety requirements issued by the following directives 9 Radio Sets 1999 05 EC 9 Low Voltage 2006 95 EC 9 Electromagnetic Compatibility 2004 108 EC and any revisions thereof and complies with the provisions that implement said directives in the National Legislation of the Country of destination where the products are to be used Sossano 24 10 2011 ...

Page 9: ...for travelling expenses and labour costs The guarantee does not cover the following cases v if the fault was caused by an installation that was not performed according to the instructions provided by the company inside the product pack v if original Quiko spare parts were not used to install the product v if the damage was caused by an Act of God tampering overvoltage incorrect power supply improp...

Page 10: ...11 11 11 10 ...

Page 11: ...11 ...

Page 12: ...facturer can technically improve the quality of its products without any prior notice Quiko Italy Via Seccalegno 19 36040 Sossano VI Italy Tel 39 0444 785513 Fax 39 0444 782371 info quiko biz www quikoitaly com ...

Reviews: