background image

 

 

two bolts hold the  metal angle retaining bar and the  cooling pads in place. Next, remove the angle retaining bar and set to 

side. Now you are ready to remove your unit’s cooling pads. 

 

7.2  Removing the cooling pads 

Before your start, make a note of the direction of the angle of the pads flutes 

(see side 

of pads).

 You must put padsback in correct order for your unit to function 

 

effectively. (Note: Install steep side 45° angle flute to the back of unit.) 

Once the retaining angle bar is removed from the top of your QuietCool unit, reach to the  

top of the dry cooling pad to the left and gently take hold of the top of the pad and gently  

pull back and slightly down – this action will loosen the pad from the unit. Look at the  

direction of the angle of the pad flutes 

(side of pads

). Remove the cooling pad and proceed  

to the nextpad. Then, remove all five cooling pads and gently set in a safe place.  

Note: this is a good time to take the cooling padsoutside and run clean water over the pads to remove any accumulated dirt  

and debris. 

Do not use high pressure hose

 – this will damage pads and their ability to function effectively. Make sure the  

pads are thoroughly dry before placing back inside the unit. Full exposure to the sunlight is a good way to dry the pads  

while helping remove mold and mildew. 

 

7.3  Daily maintenance 

15 minutes before quitting time – turn off the water pump and let the fan run 10 – 15 minutes – to dry out the cooling pads 

before leaving. Inspect the cooling pads to make sure they are thoroughly dry (this action helps to reduce mold and mildew) 

when pads are completely dry then turn-off fan. 

 

7.4  Periodic maintenance 

Depending upon your environment and how often you operate your QuietCool will depend on how dirty your water gets in 

the reservoir and how often you will need to clean it. If you begin to detect an algae smell coming from your unit – it’s time 

to  flush  your  QuietCool  reservoir  with  fresh  water.  Refer  to  and  follow  the  steps  above  in  7.2  and  you  will  only  need  to 

remove 1 or 2 of the cooling pads from the left side of the unit to gain access to your water reservoir. Take a small sponge 

and clean out your water reservoir with a light cleaner and wipe it down completely and let the unit dry.  (You may want to 

use a wet / dry shop vacuum to clean out unit). When unit is clean add an Evap-O-Matic tablet – then replace your cooling 

pads (make sure flutes are facing correct direction) retaining bar and bolts and add fresh, clean water back to the units’ water 

reservoir. Note: Adding Evap-O-Matic helps to reduce algae, mold and mildew. You can get the tablets by ordering from the 

QuietCool  order  form  found  in  section  9.0.  Simply  follow  instructions  on  the  label.  You  may  want  to  consider  a  Water 

Stabilizer to remove harmful calcium, scale build-up and algae – see section 9.0. 

Note: You may want to remove most of water from water reservoir by attaching a garden hose to the drain valve and place 

the end of the garden hose into a drain then, running pump until sump is dry – shutting off pump immediately.  

Warning! Do not run pump without water in the reservoir.

 This action will burn up your QuietCool’s water pump. 

 

 

 

 

 

Summary of Contents for QC36B1

Page 1: ...Drive 1 Speed QC36DVS QuietCool 36 Direct Drive Variable Speed shown above QC36B1 QuietCool 36 Belt Drive 1 Speed HP QC36B1X QuietCool 36 Belt Drive 1 Speed HP QC36B3 QuietCool 36 Belt Drive 3 Speed...

Page 2: ...ufactured for another voltage frequency configuration See manufacturer s label on cooler A ground fault circuit interrupter protected circuit is strongly recommended WARNING Check your units electric...

Page 3: ...ater flow 5 4 Turn on Fan 6 0 Daily Operating procedures 6 1 Turn on pump 6 2 Adjust water flow 6 3 Turn on fan 6 4 Turn off unit 7 0 Maintenance 7 1 Access inside of unit 7 2 Removing the cooling med...

Page 4: ...Cooling Works Keeping in mind that regular fans only circulate same temperature air same humidity your QuietCool portable evaporative cooler takes that same existing air combines it with evaporating w...

Page 5: ...o obstructions between your QuietCool and the people area you need to cool 5 1 Filling the units reservoir with water Once your water hose is connected open the water flow valve located on the front o...

Page 6: ...our QuietCool operates most efficiently and maintains uniform cooling pad wetness with the water control valve turned on at 1 turns You must determine what works best for you and your specific environ...

Page 7: ...ng pads to make sure they are thoroughly dry this action helps to reduce mold and mildew when pads are completely dry then turn off fan 7 4 Periodic maintenance Depending upon your environment and how...

Page 8: ...y operate at peak performance at 1 turns Repair as necessary Reduce the water flow with the water control valve located on the front of the unit Search for leaks and repair as necessary Push bottom of...

Page 9: ...y See section 7 4 8 0 Storage Remove pads as described above in 7 2 and rinse pads clean with fresh water Dry cooling pads in sunlight Drain water reservoir completely and wipe dry Replace dry cooling...

Page 10: ...chemical water treatment tablets that stops scale and calcium deposits associated with hard water Adds life to vital cooler equipment increases cooling efficiency and ends swampy odors Treatment 2 tab...

Page 11: ...st time QCPUMP Replacement Pump for all 36 units Simply replace the new pump with the old pump List 168 00 each TR798 Float Valve for all 36 units Automatically adjusts water level in units reservoir...

Page 12: ...t Automatically adjusts water level TR798 List 16 00 each Inline filter Catches large debris in water line to cooling pads 12Filter List 23 00 each Replacement Caster Straight Wheel Sold in set of 2 Q...

Page 13: ...13 12 0 Wiring Diagrams for all 36 units...

Page 14: ...14...

Page 15: ...15...

Page 16: ...the defective product or part damages due to removal or any expenses incurred in shipping the product of part to or from Quietaire Cooling plant or the installation of the repaired or replaced produc...