6
open the valve to 1 ¼ turn. Allow water to run for 10 – 15 minutes on new cooling pads to totally saturate them with water.
Once your units cooling pads are saturated – then, you are ready to turn on fan and begin to feel the cooling effect from your
new QuietCool. Note: After your cooling pads are broken in (typically takes 1 -2 weeks in operation) it will take less time to
saturate pads for start-up.
5.4 Turn-on Fan
Once your cooling pads are wet – you may turn on your QuietCool unit. Now you can begin to feel the QuietCool difference
in temperature. After your QuietCool has run for 5 minutes or so, visually inspect the pads – if water is dripping outside the
unit – you have too much water, simply turn the water flow valve to the right ½ turn and inspect water flow in another 5
minutes. If there are dry streaks in the cel deck pads open the water flow valve handle ½ turn to increase water – check water
flow in another 5 minutes and adjust accordingly. Most QuietCool operations work effectively with valve opened at 1 ¼
turns. This water valve is efficient – it requires minimal turning.
6.0 Daily Operating procedures
6.1 Turn-on water pump
Turn on water pump to unit – then, turn on fan to low – let cooling pads get saturated – then turn fan on high for cooling.
Adjust the water flow – Your QuietCool operates most efficiently – and maintains uniform cooling pad wetness with the
water control valve turned on at 1 ¼ turns. You must determine what works best for you and your specific environment.
6.2 Adjust water flow
Your QuietCool operates most efficiently – and maintains uniform cooling pad wetness with the water control valve turned
on at 1 ¼ turns. You must determine what works best for you and your specific environment.
6.2 Turn on fan
When you can see that the cooling pads are saturated with water – turn fan on high and feel the cooler air coming from your
QuietCool unit. Adjust the fan speed for your comfort.
6.4 Turn-off unit at end of day
15 minutes before closing for the day – turn off water pump with toggle switch – leave fan running – this action will shut-off
water to the cooling pads while keeping the fan running. The fan will dry out the cooling pads. When the cooling pads are
thoroughly dry – turn off fan. Drying your cooling pads thoroughly - everyday will help prevent mold and mildew growth,
plus it will prolong the life of your cooling pads.
7.0 Maintenance
7.1 Access inside of unit
Turn-off water pump and let the fan continue to run until the cooling pads are thoroughly dry (about 10 – 15 minutes). Once
your cooling pads are completely dry you may turn-off fan. Now unplug electricity to unit to avoid unnecessary shock. Next,
using a 7/16” wrench – remove the two retaining bolts from the backside and topside (cooling pad side) of the unit. These