7.1 Soldering Technology
1
.
Turn on power switch of each part.
2
.
Move PCB Fixture with fixed PCB to make PCB over the Bottom Heater and make the soldered
component between Top Heater and Bottom Heater. The position is easy to be measured with
laser alignment device. The right position should make the red laser point in the center of
component. The component which to solder on the PCB have been aligned before soldering.
Suggest using PL precision placement system.
3
.
Select parameter with keyboard. (Refer to “Parameter setting”)
1) Input password”000”
2) Select the required flow, if need to modify, perform relevant operation.
3) Select “solder” working mode.
4) Select “IR” laser alignment mode.
5) Not to change communication speed, and press “EXIT” key to exit. IR window shows:
6) Press “START” key and the system start to work, perform content of selected flow.
4. IR window will show series of setting temperatures and the current temperature of Tb and TC
during working, and indicate when it reaches T0, T1, T2, T3 and TL. S1, S2 and S3 are counted
down and user can know about the setting value clearly.
5. IR window will show series of setting temperatures and the current temperature of Tb and TC
during working, and indicate when it reaches T0, T1, T2, T3 and TL. S1, S2 and S3 are counted
down and user can know about the setting value clearly.
6. If you see the solder has melted down (It is watched with IR camera and LCD), you can press
“CAL” Key to calibrate temperature of TL to adjust the display temperature to liquid temperature
TL.
7. When the temperature reaches TL, there will be a voice signal.
8. When the temperature reaches T3, the voice signal is change to a hurry sound and the system
prolongs heating by S3 seconds, after it, the system will not heat up anymore, and the technical
process is over.
9. The system can perform a series of function action during working.
a) After press “START” key, the top heater move downwards near to bottom.
b) After the system sounds unvaryingly, the top heater moves upwards. Open the cooling fan
to blow cooling wind.
c) After the PCB has cooled, close the cooling fan, and the soldering technics has finished.
TC: ***
℃
Tb: ***
℃
ready for flow
TC:022
˙
C Tb:019
˙
C
ready for flow
Summary of Contents for QUICK7610
Page 19: ......