INTRODUCTION:
The OBAE line of chargers are designed for the permanent installation on battery powered
vehicles and equipment. They are an electronically controlled two stage charger. The first stage
brings the batteries to the gassing threshold where a three hour timer starts. The batteries are then
gassed for three hours. After three hours, the charger drops into a low float mode where the
charge is maintained in the batteries indefinitely. Finish current is below 1 amp.
SOME APPLICATIONS:
Golf cars, pallet trucks, personnel carriers, scissor lifts, floor scrubbers, stand-by power
applications, robotics.
IMPORTANT: DO NOT USE THIS CHARGER UNTIL YOU HAVE READ ALL THE
INSTRUCTIONS.
INITIAL INSTALLATION:
Before making AC connections, refer to the AC requirements labeled on the charger. If your
charger is not equipped with an AC plug (a 220 volt model) have a qualified electrician install
one.
CAUTION: To reduce the risk of fire, use this charger only on circuits provided with
a maximum of 20 ampere branch circuit protection (circuit breaker or fuse),
In accordance with the National Electric Code, ANSI/NFPA 70, and all local
codes and ordinances.
GROUNDING INSTRUCTIONS:
This battery charger must be grounded to reduce the risk of electric shock. If the charger is
equipped with a grounding type plug, it must be plugged into a nominal 115 volt, 60 Hertz circuit.
If the charger is supplied with no plug, have a qualified service person install one.
WARNING: Improper connection of the equipment grounding conductor can result in a
risk of an electric shock. DO NOT USE THIS CHARGER ON A TWO
POLE UNGROUNDED OUTLET OR ATTEMPT TO BREAK OFF THE
GROUND PRONG FOR USE ON A RECEPTACLE OR EXTENSION
CORD NOT HAVING A GROUND.
The use of an extension cord with this charger should be avoided. The use of an improper
extension cord result in a risk of a fire or electric shock. If an extension cord must be used, make
sure it is in good condition. Use a three conductor cord no smaller than 14 AWG. And keep it as
short as possible. Locate all cords so that they will not be stepped on, tripped over, or otherwise
subjected to damage or stress.
Do not operate this charger if it shows any signs of physical damage.