Quick Charge MB Multi MB1210X2 Operating Instructions Manual Download Page 1

 
 
 
 
 
 
 
 
 
 
 
 

O P E R A T I N G   I N S T R U C T I O N S 

                    MB Multi Bank Battery Chargers  

Models

MB1210X2, MB1210X3, MB1210X4, MB1210X6, MB1210X10, MB1210X12 

For Industrial Use:

 

Designed for gel, wet cell, AGM, and Lithium Ion Batteries

 

                                   (Lithium ion applications 

must be factory programmed

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
Quick Charge Corp. 
800 658-2841 
e-mail 

[email protected]

 

www.quickcharge.com

 

Made in the U.S.A 

101712 

Summary of Contents for MB Multi MB1210X2

Page 1: ...10X2 MB1210X3 MB1210X4 MB1210X6 MB1210X10 MB1210X12 For Industrial Use Designed for gel wet cell AGM and Lithium Ion Batteries Lithium ion applications must be factory programmed Quick Charge Corp 800...

Page 2: ...charger see ratings label on charger Charging a battery with a lower voltage rating than the charger will cause damage to batteries charger and can create an explosive atmosphere Plug the charger into...

Page 3: ...set so it will be something less than a 10 amp incremental increase Please read complete instructions before proceeding SAFETY INFORMATION AC WIRING Before making AC connections refer to the requirem...

Page 4: ...ted to damage or stress OTHER SAFETY INFORMATION Do not use charger if it shows signs of physical stress or if DC output leads or connector feel hot when used Do not disconnect the DC output clamps or...

Page 5: ...s soon as possible after a deep discharge but not if they are warm allow a cooling down period Provide adequate ventilation when charging batteries Chargers can ignite flammable materials and vapors D...

Page 6: ...ce mode assures batteries will remain charged and won t self discharge IMPORTANT Use switch numbers as a guide as some boards may be upside down and reversed NOTE The 1 position is designated for batt...

Page 7: ...oming out when I plug it in The charger must be connected to a battery to turn on The batteries don t receive a full charge On wet cells the specific gravity will not rise to a full reading after the...

Page 8: ...the branch circuit fuse circuit breaker a short while after being switched on The branch circuit is too small Relocate charger to a branch circuit with a heavier rating or remove other loads on the ci...

Page 9: ...Quick Charge or if the charger or component have been subjected to misuse negligence or harsh environmental conditions Except those chargers designed for such conditions If returning the charger to t...

Reviews: