WARNING

READ AND SAVE THESE INSTRUCTIONS

Installer: Leave this manual with the homeowner.

CAUTION

CLEANING & MAINTENANCE

OPERATION

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up.

3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.

4. Please read specification label on product for further information and requirements.

For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with the dust brush attachment.

The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the motor with the 

exact service motor. The impeller should also be replaced.

VENTILATION FAN

a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

b). Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on 

accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

c). Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including 

fire-rated construction codes and standards.

d). Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. 

Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association 

(NFPA),and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

e). When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

f). Ducted fans must always be vented to the outdoors.

g). Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch 

circuit (ceiling installation only).

h). This unit must be grounded.

i). Not for Use in Kitchens.

j). To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces within walls or ceilings or into 

attics,crawl spaces, or garages.

k). WARNING: To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control Device.

Cod: 0060300000-A

Model:

SL100-3H

SL100-3HM

SL100-3

Humidity sensor knob

(For SL100-3H and SL100-3HM)

50

 80

  100

1 2

1 2

1 2

Switch position

Duct  diameter

Airflow(CFM)

4"

Low airflow knob

Control box

To change the pre-selected airflow, adjust

the control switches as per the table above.

is the position of switch

See “Connect Wiring” for details.

The control box, located inside the fan housing, has three separate adjustments: 

(1) the low airflow knob adjusts the lower airflow from 30 CFM up to the air flow rate of the high fan speed determined by the toggle switch setting.

     The low speed is de-activated when set between OFF-30 CFM (factory set to OFF).

(2) (For SL100-3H and SL100-3HM) the humidity sensor knob set user-adjustable setpoint. Factory set to 80% (Ambient temperature of 25

 

).

      (Only for SL100-3) The time delay knob is adjustable from 3 to 30 minutes and will switch the fan to the low speed setting after the switch 

II

 is turned off for the set period of time.

     The time delay setting is de-activated when set between OFF-3 mins (factory set to OFF).

(3) The toggle switch will adjust the upper fan speed setting from 50 to 100 CFM. (factory set to 100CFM).

time delay knob

(Only for SL100-3)

50

 80

  100

1 2

1 2

1 2

Switch position

Duct  diameter

Airflow(CFM)

4"

Low airflow knob

Control box

To change the pre-selected airflow, adjust

the control switches as per the table above.

is the position of switch

S

Max.

30

CFM

OFF

50%

70%

H (%)

80

45

60

30

S

Max.

30

CFM

OFF

50%

70%

T(min)

OFF

30

12

21

3