iDRAC Direct LED indicator codes
17
Convention
Power indicator
pattern
Condition
CAUTION:
When correcting a PSU mismatch, replace only
the PSU with the flashing indicator. Swapping the PSU
to make a matched pair can result in an error condition
and unexpected system shutdown. To change from a high
output configuration to a low output configuration or vice
versa, you must turn off the system.
CAUTION:
AC PSUs support both 220 V and 110 V input
voltages with the exception of Titanium PSUs, which
support only 220 V. When two identical PSUs receive
different input voltages, they can output different wattages,
and trigger a mismatch.
CAUTION:
If two PSUs are used, they must be of the same
type and have the same maximum output power.
CAUTION:
Combining AC and DC PSUs is not supported
and triggers a mismatch.
E
Not lit
Power is not connected.
iDRAC Direct LED indicator codes
The iDRAC Direct LED indicator lights up to indicate that the port is connected and is being used as a part of the
iDRAC subsystem.
NOTE:
The iDRAC Direct LED indicator does not turn on when the USB port is used in the USB mode.
Figure 6. iDRAC Direct LED indicator
1. iDRAC Direct status indicator
The iDRAC Direct LED indicator table describes iDRAC Direct activity when configuring iDRAC Direct by using
the management port (USB XML Import).
Table 7. iDRAC Direct LED indicators
This table describes the iDRAC Direct status indicators and what is the condition when the LED flashes green, continuously
flashes green and when it’s not lit.