UMTS/HSPA Module Series
UG96 Hardware Design
UG96_Hardware_Design 26 / 76
In sleep mode, the module can still receive paging message, SMS, voice call and TCP/UDP data from the
network normally.
3.5.2. Minimum Functionality Mode
Minimum functionality mode reduces the functionality of the module to minimum level, thus minimizes the
current consumption at the same time. This mode can be set as below:
Command
AT+CFUN
provides the choice of the functionality levels: <fun>=0, 1, 4.
⚫
AT+CFUN=0
: Minimum functionality, RF part and (U)SIM card will be closed.
⚫
AT+CFUN=1
: Full functionality (by default).
⚫
AT+CFUN=4
: Disable RF function (airplane mode). All AT commands related to RF function are not
accessible.
For detailed information about command
AT+CFUN
, please refer to
document [1]
.
3.6. Power Supply
3.6.1. Power Supply Pins
UG96 provides four VBAT pins for connection with the external power supply. There are two separate
voltage domains for VBAT.
⚫
Two VBAT_RF pins for module RF part.
⚫
Two VBAT_BB pins for module baseband part.
The following table shows the details of VBAT pins and ground pins.
Table 6: VBAT and GND Pins
Pin Name
Pin No.
Description
Min.
Typ.
Max.
Unit
VBAT_RF
52, 53
Power supply for module
’s RF
part.
3.3
3.8
4.3
V
VBAT_BB
32, 33
Power supply for module
’s
baseband part.
3.3
3.8
4.3
V
GND
3, 31, 48, 50
54, 55, 58,
Ground
-
-
-
-
NOTES